Re-assembly Procedure

36.    

By means of a mallet put back the motor 

fan.

37.    

Position the motor fan cover and tighten 

it firmly.

Summary of Contents for FPS MH Series

Page 1: ...50 Hz Horizontal Multistage Centrifugal Pumps Assembly and Disassembly Instructions...

Page 2: ......

Page 3: ...f fan cover and remove it 3 Remove the plugs from the pump casing 5 Remove the motor holder 2 Remove the fan by means of a screwdriver 4 Using a bench vice lock the pump from the motor shaft then rele...

Page 4: ...c tool pipe having very fine wall between the rubber of the mechanical seal and the shaft Pull the tool holding the mechanical seal upwards to the end of the shaft 8 Unscrew and then remove the impell...

Page 5: ...atic portion of the mechanical seal from the seal plate 15 Pull out together the rotor and motor flange 17 Extract the rotor from the motor flange 14 Unscrew and then remove the tie bolts 16 Remove th...

Page 6: ...e 20 Place the compensation spring on top of motor bearing 22 Insert and fasten the tie bolts 19 Couple the stator 19 Insert the rotor into motor flange with motor flange 21 Couple the motor flange 23...

Page 7: ...o its housing 26 Lubricate the mechanical seal and slide it down on the shaft If available use the supplied tool to ease this operation 28 Position the washer split rings and disk 25 Place the seal pl...

Page 8: ...ts washer 32 Lubricate the O ring with alcohol and then position the pump casing 34 Secure the pump casing to the motor by tightening the pre loading screws 31 Couple the O ring to the seal plate 33 P...

Page 9: ...7 Re assembly Procedure 36 By means of a mallet put back the motor fan 37 Position the motor fan cover and tighten it firmly...

Page 10: ...8 Notes...

Page 11: ...9 Notes...

Page 12: ...LIA NEW ZEALAND Franklin Electric Australia Pty Ltd 106 110 Micro Circuit Dandenong South Victoria 3175 Australia Toll Free 1300 FRANKLIN 1300 372 655 Fax 61 3 9799 5050 Tel 61 3 9799 5000 www frankli...

Reviews: