Disassembly Procedure
7.
Remove the O-ring from the seal plate.
9.
Remove stages, spacers and impellers.
11.
Insert the specific tool /pipe having very
fine wall) between the rubber of the
mechanical seal and the shaft. Pull the
tool holding the mechanical seal
upwards to the end of the shaft.
8.
Unscrew and then remove the
impellers’ pre-loading nut and washer.
10.
Remove the mechanical seal locking
disk, split rings and washer.
12.
Pull out the seal plate.