10.

Slowly turn on the water supply valve. Open faucet until 

water flows  for about one minute. Check all connections 

for leaks.

11 .

Plug  in  the  chiller.

12 .

Prior  to  drinking  water  from  chiller,  fl ush  water 

through  the  chiller  for  about 5 minutes.

5

If local codes permit, the chiller feed line should be connected

to the cold water supply line with a ‘’T’’ water line connector

(sold separately). If you are using a filtration  unit, the chiller

should be connected after the filters.

IM PORTANT:

If local codes do not permit the use of the ‘’T’’

water line connector, special feed valves can be obtained from

your local plumbing supply retailer.

Caution:

The feed valve must allow water to flow  back into the

building’s water supply piping to avoid extreme pressure building

up as the water is chilled. Failure to relieve this pressure will

damage the chiller  system and  result  in a water  leak. 

The water pressure to the chiller should be between 30 psi  (MIN )

and  100  psi (MAX).

Installation  Instructions

6b.

If  you are NOT installing a filtration system, connect blue 

tubing between the”water out” chiller tube and faucet, sold

seperately. Do NOT use “T” quick 

fittings (part  10)  or 

check valve (part  11).

7.

Cut 6 inches of white tubing. Connect one end to “T” 

(part  10) that is connected  to “water out” chiller tube and   

other end to check valve inlet ( see figure 2).

8.

Cut white tubing to connect the water supply fitting  

(part 7) and  the inlet of the filtration  system. Connect the  

straight-thru ports of the second “T” (part  10)  to  the  loose   

ends of the white tubing just cut. (see figure  3)

9.

Connect white tubing included with chiller between the third 

port of the second “T” (part  10) and check valve outlet (see   

figure  3).

Figure 2

Water Supply Requirements

Install the Chiller

Figure 1

Collet

Body

Tube

Figure A

Figure B

Figure C

Check valve
(part 11 )

White tubing
to check valve

Blue tubing to faucet

“T” Quick connect fitting
(part 10 )

Connection to Chiller
water “out”

Figure 3

Check valve
(part  11 )

White tubing
to filtration 

Connection to part  7

“T” Quick 
connect fitting
(part 10 )

part 10

part 7

part 10

N OTE: 

Tubing must be cut to fit.  All tubes must be cut squarely

with no burrs. All tubing connections must be fully seated.

Tubing must be routed to avoid sharp bends and have enough

slack to avoid straining connections. A P-clip and mounting

screw are included to hold the tubing in place as needed. Pull

gently on each connection to make sure they are secure.

IM PORTANT: 

After chiller is unpacked, place chiller upright for

24 hours before plugging it in.

1.

Determine where you will install your chiller. 

See ‘’Location Requirements’’ section.

2 .

For  best  performance,  allow a 2”  (5  cm)  space  around 

the  side  and  the  top.  Do  not  put  any  objects  on  top  of 

the  chiller  that  could  obstruct  the  fan.

3.

Shut off water supply valves.

4.

Install faucet (sold separately). 

See faucet’s Installation instructions.

5.

Cut a piece of white tubing to connect the chiller (water in) 

to the water supply fitting (part 7) or filter outlet (if applicable).

(see  figure  1)

N OTE: 

If you are installing the chiller and a filtration system

without a bladder tank, follow steps 6a to 12.  Following these

steps will avoid the possibility of excessive pressure building as

the chiller cycles on and off. If you are installing a bladder tank

with your filtration system, the bladder tank must be connected

directly  to  the  chiller  without  any  regulators  or  back  flow

preventers between them. If you are NOT installing the chiller

with a filtration system or if your filter system includes a bladder

tank, follow steps 6b. and 10 to  12.

6a.

Connect  “T” (part 10) to “water out“ chiller tube. Connect blue

tubing between “T” and faucet, sold separately. (see figure 2)

How  to insert/remove  tubing  in  easy  connect  fitting

Insert the tubing squarely. See figure  A.

Make sure to insert tubing completely. See figure  B.

Push in collet and pull out tubing. See figure  C.

6.  Connect elbow fittings to chiller inlet and outlet tubes.

7.  Connect water supply tube to fitting on chiller “water in.”

8.  Connect faucet tubing to chiller “water out.”

9.  Slowly turn on the water supply valve. Open faucet until

     water flows for about one minute. Check all connections 

     for leaks.

10. Plug in the chiller.

11. Prior to drinking water from chiller flush water through the 

      chiller for about 5 minutes.

Figure 1

Summary of Contents for KER1P

Page 1: ...etien Questions sur les caract ristiques prix de vente sugg r op ration rendement pi ces accessoires ou service appelez au 1 855 446 5663 Table of Contents Table des mati res 2 This chiller unit is no...

Page 2: ...ppen if the instructions are not followed 2 Table of Contents CHILLER SAFETY 2 ASSISTANCE OR SERVICE 3 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Electrical Requirements 4 W...

Page 3: ...p is available by calling 1 800 950 3226 Monday to Friday 8 00 a m 6 00 p m EST or write Oasis International 222 East Campus View Blvd Columbus OH 43235 Please include a daytime phone number in your c...

Page 4: ...ounded electrical supply is required This drinking water cooler is intended to be connected to a ground fault circuit interrupting GFCI device to meet UL requirements It is recommended that a separate...

Page 5: ...10 part 10 part 7 part 10 NOTE Tubing must be cut to fit All tubes must be cut squarely with no burrs All tubing connections must be fully seated Tubing must be routed to avoid sharp bends and have en...

Page 6: ...iner 6 Set chiller in its normal upright position for storage Draining the Chiller 1 Shut off water supply to chiller 2 Put chiller in position allowing a 2 5 cm space around the side and top 3 Connec...

Page 7: ...water line If so attach to cold water line Cold water in tank is still being chilled Wait 15 minutes and check temperature again Check that the Temperature Control is set to the Max setting Cold water...

Page 8: ...ques potentiels pouvant causer des blessures ou la mort vous ou d autres Tous les messages de s curit suivent le symbole d alerte et les mots DANGER ou AVERTISSEMENT Ces mots signifient Le non respect...

Page 9: ...itionnelle est disponible en appelant au 1 800 950 3226 du lundi au vendredi de 8 h 18 h heure de l Est ou en crivant Oasis International 222 East Campus View Blvd Columbus OH 43235 USA Veuillez inclu...

Page 10: ...une prise lectrique appropri e n est pas disponible c est la responsabilit et l obligation du consommateur de faire installer par un lectricien qualifi une prise 3 dents connect e terre 3 1 Refroidiss...

Page 11: ...un r servoir de d lestage avec votre syst me de tion le r servoir doit tre connect directement au refroidisseur sans aucun r gulateur de pression Si vous n installez pas un syst me de avec votre refro...

Page 12: ...minimalement de 30 psi 138 kPa L eau a une saveur d sagr able J Si le distributeur n a pas t utilise depuis 3 jours ou plus ou si seulement 1 3 tasses d eau sont distribu es par jour le r servoir peut...

Page 13: ...froidisseur peut causer des d g ts d eau des chocs lectriques ou des incendies Sauf pour ce qui est ici crit ou ce qui est requis par la loi le garant n offre aucune autre garantie caution ou accord e...