background image

6

036865-004        

0112

7

0112

        036865-004   

MODULAR SPORTS BOTTLE FILLER

 

InSTRUcTIOnS FOR MODELS: KEMWSBF, KEMW8SBF, KEMW12SBF,  

KEM8SBF, KEM12SBF

MODULAR SPORTS BOTTLE FILLER

 

InSTRUcTIOnS FOR MODELS: KEMWSBF, KEMW8SBF, KEMW12SBF,  

KEM8SBF, KEM12SBF

 

CHILLER

FRONT OF CHILLE

R

 

IN

OUT

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" TAILPIECE

PROVIDED BALL

VALVE AND 3/8" O.D.

COPPER TUBE

CONNECT TO

BUILDING WATER

SUPPLY

1/4" UNION

FTGS. PROVIDED

FILLER DELIVERY

TUBE

TO CHILLER 

OUT

OPTIONAL FILTER

LOCATION WITH

CHILLER

TO CHILLER

 IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

FROM

SOLENOID

VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

STEM

ELBOWS

 

CHILLER

FRONT OF CHILLE

R

 

IN

OUT

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" TAILPIECE

PROVIDED BALL

VALVE AND 3/8" O.D.

COPPER TUBE

CONNECT TO

BUILDING WATER

SUPPLY

1/4" UNION

FTGS. PROVIDED

FILLER DELIVERY

TUBE

TO CHILLER 

OUT

OPTIONAL FILTER

LOCATION WITH

CHILLER

TO CHILLER

 IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

FROM

SOLENOID

VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

STEM

ELBOWS

STEP 4: KEMW8SBF AnD KEMW12SBF (cOnnEcTInG ThE chILLER)

a)  Attach cradle to frame per rough in drawing (Screws provided - 4).
b)  Place chiller in frame.
c)  Install 1/4" Union fittings on chiller inlet and outlet.
d)  Run the water line from the bottle filler solenoid valve OUT to chiller IN.    
 

Cut off excess and use it to run from chiller OUT to the bottle filler  

 

 

delivery tube.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

STEP 5: FILTER LOcATIOn (WIThIn chILLER)

a)  Screw filter clip to unit in location as shown in 

Figure 5

 (Screw provided).

b)  Install 1/4" stem elbows (provided) in filer inlet and outlet.
c)  Place filter in clip as shown in 

Figure 6

.

 
 
 
 
 
 
 

STEP 6: FILTER InSTALLATIOn (WITh chILLER)

a)  Mount filter to chiller casing (See 

Figure 6

).

b)  Install provided stem elbows.
c)  Run the water line from the bottle filler solenoid valve to the chiller inlet.
d)  Connect bottle filler solenoid valve to filter inlet.
e)   Connect filter out to the chiller inlet.

 

CHILLER

FRONT OF CHILLE

R

 

IN

OUT

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" TAILPIECE

PROVIDED BALL

VALVE AND 3/8" O.D.

COPPER TUBE

CONNECT TO

BUILDING WATER

SUPPLY

1/4" UNION

FTGS. PROVIDED

FILLER DELIVERY

TUBE

TO CHILLER 

OUT

OPTIONAL FILTER

LOCATION WITH

CHILLER

TO CHILLER

 IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

FROM

SOLENOID

VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

STEM

ELBOWS

STEP 7: chILLER AnD FOUnTAIn cOnnnEcTIOnS  

(KEM8SBF, KEM12SBF)

a)   Install chiller in frame.
b)  Install 1/4" union on chiller IN.
c)  Connect 1/4" union tee to chiller OUT.
d)  Determine tube length needed to connect bottle filler solenoid IN (The    
 

line with the attached ball valve) to chiller tee. Cut tube and connect.

e)   Attach remaining tube from ball valve to chiller IN.
f)  Remove adapter fitting and copper tube from the fountain water line.  

 

 

Install provided 1/4" union.

g)  Determine length of tube needed to connect bottle filler solenoid OUT    
 

to bottle filler delivery tube, cut off excess.

h)   Use excess tube to connect fountain to chiller tee.

 

 

 

STEP 8: FILTER cOnnEcTIOn (BOTTLE FILLER AnD FOUnTAIn)

a)  Mount filter to chiller casing (See 

Figure 5

).

b)  Install provided stem elbows (See 

Figure 8

).

c)  Cut the tube to the chiller inlet.
d)  Connect tubing from ball valve to filter IN. Connect filter OUT to chiller IN.

FRONT OF CH

ILLE

R

 

 

CHILLER

OUT

IN

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" 

TAILPIECE

DRAIN

COMPONENTS

NOT INCLUDED

SHORT RADIUS

TRAP REQUIRED

FILLER DELIVERY TUBE

1/4" UNION FITTING
1 1/4" TAILPIECE

(TRAP NOT INCLUDED)

1/4" UNION CHILLER 

IN CONNECTS TO BALL 

VALVE OF FILTER OUT 

(IF USED)FITTINGS 

PROVIDED

PROVIDED BALL

VALVE AND 3/8"

O.D. COPPER

TO BUILDING

WATER SUPPLY

1/4" UNION TEE

CHILLER 

OUT

CONNECT TO

FOUNTAIN AND

BOTTLE FILLER

SOLENOID 

IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

STEM

ELBOWS

FROM PROVIDED

BALL VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

FRONT OF CH

ILLE

R

 

 

CHILLER

OUT

IN

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" 

TAILPIECE

DRAIN

COMPONENTS

NOT INCLUDED

SHORT RADIUS

TRAP REQUIRED

FILLER DELIVERY TUBE

1/4" UNION FITTING
1 1/4" TAILPIECE

(TRAP NOT INCLUDED)

1/4" UNION CHILLER 

IN CONNECTS TO BALL 

VALVE OF FILTER OUT 

(IF USED)FITTINGS 

PROVIDED

PROVIDED BALL

VALVE AND 3/8"

O.D. COPPER

TO BUILDING

WATER SUPPLY

1/4" UNION TEE

CHILLER 

OUT

CONNECT TO

FOUNTAIN AND

BOTTLE FILLER

SOLENOID 

IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

STEM

ELBOWS

FROM PROVIDED

BALL VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

FRONT OF CH

ILLE

R

 

 

CHILLER

OUT

IN

SOLENOID

VALVE 

OUT

SOLENOID

VALVE 

IN

1 1/4" 

TAILPIECE

DRAIN

COMPONENTS

NOT INCLUDED

SHORT RADIUS

TRAP REQUIRED

FILLER DELIVERY TUBE

1/4" UNION FITTING
1 1/4" TAILPIECE

(TRAP NOT INCLUDED)

1/4" UNION CHILLER 

IN CONNECTS TO BALL 

VALVE OF FILTER OUT 

(IF USED)FITTINGS 

PROVIDED

PROVIDED BALL

VALVE AND 3/8"

O.D. COPPER

TO BUILDING

WATER SUPPLY

1/4" UNION TEE

CHILLER 

OUT

CONNECT TO

FOUNTAIN AND

BOTTLE FILLER

SOLENOID 

IN

FILTER CLIP

PLACE FILTER

IN CLIP AS

SHOWN

STEM

ELBOWS

FROM PROVIDED

BALL VALVE

TO BOTTLE

FILLER DELIVERY

TUBE

Figure 4

Figure 5

Figure 6

Figure 7

Figure 5

Figure 8

Summary of Contents for KEMWSBF

Page 1: ...MODELS WITH CHILLER h Attach cradle mounting angles to unit mounting cradle with 4 screws provided Slide unit mounting cradle into frame and secure in place with 4 screws provided Cradle is used only...

Page 2: ...NIT FRAME ASSY FURNISHED FINISHED WALL FLOOR LINE 3 1 2 89 4 5 16 110 21 9 16 548 21 3 8 644 26 5 8 677 ROUGHING IN AND DIMENSIONAL DRAWING THIRD ANGLE PROJECTION NOTES 1 RECOMMENDED ADULT HEIGHT INST...

Page 3: ...line from solenoid valve to bottle filler delivery tube See Figure 2 d Connect solenoid valve out to filter in e Connect filter out to filler delivery tube IN OUT STRAINER INSIDE OUT DRAIN ASSEMBLY 2X...

Page 4: ...ONAL FILTER LOCATION WITH CHILLER TO CHILLER IN FILTER CLIP PLACE FILTER IN CLIP AS SHOWN FROM SOLENOID VALVE TO BOTTLE FILLER DELIVERY TUBE STEM ELBOWS STEP 7 CHILLER AND FOUNTAIN CONNNECTIONS KEM8SB...

Page 5: ...nd install upper and lower front panels INLET OUTLET UV INLET OUTLET HOLE PROVIDED FOR ELECTRICAL AND WATER RUN FILLER DELIVERY TUBE SOLENOID VALVE SEE FIG 11 FOR DETAILS UV HOUSING QUARTZ SLEEVE AND...

Page 6: ...crews c Install trim bezel to frame assembly and replace bottom plate with screws d Install drain assembly snap bushings and any other accessories included with this kit e Install upper and lower fron...

Page 7: ...29994 103 ftg jg elbow plug in whi 1 15 019008 bushing strain relief sr6p34 1 16 029139 001 ftg jg elbow plug in 1 17 026630 039 screw pan hd tapping type ab 1 18 036207 001 cover activation shelf 1 1...