5. TO DIScOnTInUE USE OF SySTEMS WITh chILLER

Drain cooler when removed from service: (1) Remove grille, (2) Close supply valve, (3) Provide container to catch water, and remove drain plug.

6. MAInTEnAncE (SySTEMS WITh chILLER)

The only maintenance required is the removal of dirt and lint from the condenser. Inspection should be made at 3 month intervals. Remove the grille 
and clean the condenser with a vacuum attachment.

   

      

                      

The warranty and the Underwriters’ Laboratory listing for this machine are automatically voided if this machine is altered, modified, 

or combined with any other machine or device. Alteration or modification of this machine may cause serious flooding and/or hazardous electrical 
shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR AGREEMENT EXPRESSED, 
IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

WARnInG

19 [483]

WALL OPENING

19 3/4

[502]

9 7/8

[251]

40 [1016]

WALL

OPENING

40 3/4

[1035]

28 3/8

[721]

3 15/16 [100]

5 5/16

[136]

WATER OUTLET

AND INLET

6 7/16 [164]

JUNCTION BOX

5/16 [8] DIA. MOUNTING

HOLES 8 EACH SIDE,

4 TOP AND 4 BOTTOM

1 13/16 [46]

1/2 [13]

11 5/16 [287]

WALL OPENING

8 1/8 [206]

2 [52]

1 1/2 OR 1 1/4

IPS WASTE 

STUB OUT

1/4 OD TUBE

COOLING UNIT

WATER INLET

1 1/4 TAILPIECE

1 3/8 [35]

ELECTRICAL

CONNECTION

COOLING UNIT

FRAME ASSY

FURNISHED

FINISHED WALL

FLOOR LINE

3 1/2 [89]

4 5/16 [110]

21 9/16

[548]

21 3/8

[644]

26 5/8

[677]

ROUGHING-IN

AND

DIMENSIONAL DRAWING

THIRD ANGLE PROJECTION

NOTES:
1.  RECOMMENDED ADULT HEIGHT INSTALLATION SHOWN.
  ADJUST VERTICAL DIMENSIONS AS REQUIRED TO COMPLY
  WITH FEDERAL, STATE AND LOCAL CODES.
2. STOP VALVE, TRAP, PIPE CONNECTOR TO WASTE
  WASTE LINE NOT PROVIDED. SHORT RADIUS TRAP REQUIRED.
3.  ALL DIMENSIONS ARE IN INCHES.
  DIMENSIONS IN BRACKETS [  ] ARE IN MILLIMETERS.

MODULAR SPORTS BOTTLE FILLER - MODELS KEMWSBF, KEMW8SBF, KEMW12SBF

39 1/2

[1003]

38 3/4 [984]

WALL OPENING

19 3/4

[502]

9 7/8

[251]

REMOVE NUT AND BUTTON

FOR FLOW REGULATOR

ACCESS

3/8 O.D. WATER INLET

1 1/2 OR 1 1/4 IPS WASTE

STUB OUT 2[51]

3 [80]

TO ORIFICE

WATER OUTLET

AND INLET

5/16 [8] DIA. MOUNTING

HOLES 8 EACH SIDE, 

8 TOP AND 8 BOTTOM

1 13/16 [46]

1/2 [13]

14 [356]

5 5/16 [136]

28 3/4

[730]

TO FTN     

34 9/16

[878]

ORIFICE

27

[686]

FLOOR LINE

6 7/16 [164]

JUNCTION

BOX

COOLING 

UNIT

1 1/4 OD TAILPIECE

1 3/8 [35] ELECTRICAL

CONNECTION

FINISHED WALL

16

[406]

18 1/2

[470]

1 1/2 OR 1 1/4

IPS WASTE

STUB OUT

6 1/2 [165]

10

 1

3/

16

[2

74

]

40 3/4

[1035]

3 15/16 [100]

1 1/4 TAILPIECE

19 3/4

[502]

28 3/8

[721]

26 5/8

[677]

25 3/8

[644]

3 1/2 [89] FRAME

ALLOW ADDITIONAL

DEPTH FOR WATER

AND WASTE LINES

4 5/16 [110]

21 9/16

[548]

40

[1016]

WALL

OPENING

2 [52]

8 1/8

[206]

11 5/16 [287]

WALL OPENING

1/4 O.D TUBE

COOLING UNIT

WATER INLET

NOTES:
1.  RECOMMENDED ADULT HEIGHT INSTALLATION SHOWN. ADJUST VERTICAL DIMENSIONS AS
  REQUIRED TO COMPLY WITH FEDERAL, STATE AND LOCAL CODES.
2.  STOP VALVE, TRAP, PIPE CONNECTOR TO WASTE, WASTE LINE NOT PROVIDED. SHORT RADIUS
  TRAP REQUIRED.
3. ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKETS [  ] ARE IN MILLIMETERS.

THIRD ANGLE PROJECTION

ROUGHING-IN

AND

DIMENSIONAL DRAWING

MODULAR SPORTS BOTTLE FILLER - MODELS KEM8SBF, KEM12SBF

Summary of Contents for KEMWSBF

Page 1: ...MODELS WITH CHILLER h Attach cradle mounting angles to unit mounting cradle with 4 screws provided Slide unit mounting cradle into frame and secure in place with 4 screws provided Cradle is used only...

Page 2: ...NIT FRAME ASSY FURNISHED FINISHED WALL FLOOR LINE 3 1 2 89 4 5 16 110 21 9 16 548 21 3 8 644 26 5 8 677 ROUGHING IN AND DIMENSIONAL DRAWING THIRD ANGLE PROJECTION NOTES 1 RECOMMENDED ADULT HEIGHT INST...

Page 3: ...line from solenoid valve to bottle filler delivery tube See Figure 2 d Connect solenoid valve out to filter in e Connect filter out to filler delivery tube IN OUT STRAINER INSIDE OUT DRAIN ASSEMBLY 2X...

Page 4: ...ONAL FILTER LOCATION WITH CHILLER TO CHILLER IN FILTER CLIP PLACE FILTER IN CLIP AS SHOWN FROM SOLENOID VALVE TO BOTTLE FILLER DELIVERY TUBE STEM ELBOWS STEP 7 CHILLER AND FOUNTAIN CONNNECTIONS KEM8SB...

Page 5: ...nd install upper and lower front panels INLET OUTLET UV INLET OUTLET HOLE PROVIDED FOR ELECTRICAL AND WATER RUN FILLER DELIVERY TUBE SOLENOID VALVE SEE FIG 11 FOR DETAILS UV HOUSING QUARTZ SLEEVE AND...

Page 6: ...crews c Install trim bezel to frame assembly and replace bottom plate with screws d Install drain assembly snap bushings and any other accessories included with this kit e Install upper and lower fron...

Page 7: ...29994 103 ftg jg elbow plug in whi 1 15 019008 bushing strain relief sr6p34 1 16 029139 001 ftg jg elbow plug in 1 17 026630 039 screw pan hd tapping type ab 1 18 036207 001 cover activation shelf 1 1...

Reviews: