background image

 

 

 

 

 

EN 

8

 

USE

 

A

B

C

D

E

F

G

H

Control panel 

 
 

Button

 

Function

 

Display

 

A

 

Turns the suction motor on and off at speed one. 

Displays the set speed 

B

 

Decreases the working speed. 

Displays the set speed 

C

 

Increases the working speed. 

Displays the set speed 

D

 Activate 

intensive

 speed from any other speed, 

including motor off. This speed is set to operate 
for 10 minutes, after which the system returns to 
the speed that was set before. Suitable to deal with 
maximum levels of cooking fumes. 

Displays 

HI

 and the time remaining once very second. 

 

Press and hold the button for approximately 5 
seconds, with all the loads turned off (Motor and 
Lights), to turn the Activated Charcoal Filter 
alarm On and Off. 

FC

+

Punto

 (2 flashes)–Alarm On. 

FC

+

Punto

 (1 flash)–Alarm Off. 

E

 

24H function 

Turns the suction motor on at speed one and 
effects one 10 minute extraction every hour.  

Displays 

24

 and the spot at the bottom right flashes once 

every second, while the motor is running. 
It is disabled by pressing the button. 

 

When the filters alarm is triggered, the alarm can 
be reset by pressing and holding this button for 
approximately 3 seconds.  
These indications are only visible when the motor 
is turned off. 

FF

 flashes three times. 

 
 
When the procedure terminates, the indication shown 
previously turns off: 

FG

  indicates the need to wash the metal grease filters. 

The alarm is triggered after the Hood has been in 
operation for 100 working hours.  

FC

  indicates the need to change the activated charcoal 

filters, and also to wash the metal grease filters. The alarm 
is triggered after the Hood has been in operation for 200 
working hours. 

F

 

Delay function 

 

Activate automatic switch-off with a 30’ delay. 
Suitable to complete elimination of residual 
odours. Can be activated from any position, and is 
disabled by pressing the button or turning the 
motor off. 

Displays the operating speed and the spot at the bottom 
right flashes once a second. 

 

Press and hold the button for approximately 5 
seconds, with all the loads turned off (Motor and 
Lights), to turn the Remote Control On and Off. 

IR

+

Punto

 (2 flashes)–Alarm On. 

IR

+

Punto

 (1 flash)–Alarm Off. 

G

 

Turns the lighting system on and off at maximum 
intensity. 

 

H

 

Turns the Courtesy Lighting on and off. 

 

Summary of Contents for FMY 917 XS-CH

Page 1: ...lation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullanım ve montaj talimatları Davlumbaz FMY 917 XS CH GB IT FR DE TR ...

Page 2: ...CHE 13 INSTALLAZIONE 14 USO 17 MANUTENZIONE 18 SOMMAIRE CONSEILS ET SUGGESTIONS 21 CARACTERISTIQUES 22 INSTALLATION 23 UTILISATION 26 ENTRETIEN 27 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 30 CHARAKTERISTIKEN 31 MONTAGE 32 BEDIENUNG 35 WARTUNG 36 IÇERIKLER TAVSIYELER VE ÖNERILER 39 ÖZELLIKLER 40 MONTAJ 41 KULLANIM 44 BAKIM 45 EN IT FR DE TR ...

Page 3: ...s other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance is not inte...

Page 4: ...er Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 15 14 1 7 2 1 7 3 11 12a 11 12a 12c 9 2 2 1 2 2 1 ...

Page 5: ... wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the wall plugs 11 in the hol...

Page 6: ...tion insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 RECIRCULATION VERSION AIR OUTLET Insert the connection extension pieces laterally 14 1 in connec tion 15 Insert the Connector 15 into the Support bracket 7 3 and fix it with a screw Make sure that the outlet of the extension...

Page 7: ...the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure th...

Page 8: ...ilters alarm is triggered the alarm can be reset by pressing and holding this button for approximately 3 seconds These indications are only visible when the motor is turned off FF flashes three times When the procedure terminates the indication shown previously turns off FG indicates the need to wash the metal grease filters The alarm is triggered after the Hood has been in operation for 100 worki...

Page 9: ...s Pull the Comfort Panel to open it Disconnect the panel from the hood canopy by sliding the fix ing pin lever The comfort panel must never be washed in a dishwasher Clean the outside by using a damp cloth and neutral liquid de tergent Clean the inside as well by using a damp cloth and neutral de tergent do not use wet cloths or sponges or jets of water do not use abrasive substances When the abov...

Page 10: ... Press button E see the paragraph on Use Cleaning the Filters Open the Comfort panels by pulling on the recess Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing If the surface of the filter changes colour as time goes by this will have absolutely no...

Page 11: ... DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button E see the paragraph on Use Changing the Filter Open the Comfort panels by pulling on the recess Remove the Metal grease filters Remove the saturated charcoal filter by releasing the fixing hooks Fit the new filter and fasten ...