17
FAULT FINDING / ABNORMAL OPERATION
FAULT FINDING / ABNORMAL OPERATION
_______________________________________________________________________________________________________________________
FAULT
POSSIBLE SOLUTION(S)
BURNER LIGHTS, BUT GOES OUT WHEN CONTROL IS RELEASED
(GAS)
CONTROL KNOB IS TO BE PRESSED DOWN FIRMLY, AND HELD
FIRMLY, DURING IGNITION PROCEDURE FOR 5 SECONDS.
CONTROL KNOB IS BOTTOMING OUT ON THE CONTROL PANEL AND
NOT ENGAGING THE FLAME FAILURE DEVICE
– HOLE IN KNOB NEEDS PACKING.
IF THIS IS A FAULT PRESENT ON THE WOK BURNER, REFER TO THE
CORRECT ASSEMBLY INSTRUCTIONS.
UNIT OCCASIONALLY EMITS A SPARK EVEN WHEN NOT BEING
OPERATED (GAS)
THIS USUALLY MEANS SOME MOISTURE ON THE SWITCHING
MECHANISM DUE TO SPILLAGE OR STEAM. IT SHOULD SELF RECTIFY
FLAME ON WOK BURNER PRESENT UNDER SKIRT AND LARGE
BILLOWING FLAME IN MIDDLE OF BURNER. (GAS)
FullSpectrum BURNER IS INCORRECTLY ASSEMBLED OR FOOD HAS
BLOCKED PORTS. REFER TO ASSEMBLY INSTRUCTIONS. OR CLEAN.
CONTINUED OPERATION IN THIS CONDITION MAY CAUSE DAMAGE.
RECTIFY IMMEDIATELY