24
Safety functions and error display.
ERROR CODE
ERROR DESCRIPTION
INSTRUCTION MANUAL
ER03 &
permanent
tone
Permanent use of keys; Control unit cuts off after
10 sec. Water or cooking utensils on the glass
above the control unit
If the problem persists, CONTACT
AUTHORIZED CENTER FOR
TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER21
Control unit cuts off after controlling due to
overheating to avoid damage to electronics
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
U400
Secondary voltage of the power unit to high
(primary > 300V). Control unit cuts off after 1 sec
releasing a permanent tone. Control unit is wrongly
connected.
1)CONTACT AUTHORIZED
CENTER FOR TECHNICAL
ASSISTANCE - SPECIFYING THE
ERROR CODE 2)Contact an
electrician to check your home
supply mains.
ER22
Key evaluation defective. Control unit cuts off after
3.5 – 7.5 sec.Short-circuit or discontinuation in the
range of the key evaluation
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER36
NTC value is not within its specification (value <
200mV or > 4.9V; control unit cuts off. Short-circuit
or cut-off at NTC
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER20 Flash-failure.
Microcontroller
faulty CONTACT
AUTHORIZED
CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER40
Secondary operational voltage min.5 s too low
according identified Unterspannung 1,8V<
UPowerfail< 2,9V). Primary PTC too hot.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
E4
The message appears in the cooking zone not
configured
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER47
Communication error between TC and induction.
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
ER31
Configuration data incorrect CONTACT
AUTHORIZED
CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
E2
Overheating of the induction coils
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
E5
Error on filter board
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
E6
Error on power unit
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
E9
Coil temperature sensordefective
CONTACT AUTHORIZED CENTER
FOR TECHNICAL ASSISTANCE -
SPECIFYING THE ERROR CODE
Summary of Contents for FHBP 604 4I PW T XS
Page 29: ...29 ...
Page 30: ...30 LIB30384 ...