STANDARD MAINTENANCE AND

TROUBLE SHOOTING

CLEANING OF THE SPRAY HEAD

Any deposits which may accumulate on the nozzle can be removed by simply running 
a finger over the face of the sprayer and then running the water for a few seconds.
In extreme cases this step may have to be repeated.

REPLACING THE CARTRIDGE

1. Shut off the water supply to the faucet. 
2. Open the faucet briefly to relieve any pressure

inside the faucet. 

3. Move the faucet handles to the “OFF” position.
5. Disconnect supply lines from angle wall valves

and from diverting tee.

6. Use an adjustable wrench to untighten bottom valve

body.

7. Remove cartridge from valve body seat.
8. Install the new cartridges into valve body.
13. Re-assemble faucet in reverse order. 
14. Test for leakage.

GENERAL MAINTENANCE

Clean aerator periodically.
Do not use harsh detergents, solvents, chemical agents, metallic sponges, etc. that could 
harm the surface and damage the finish.
Clean only with a soft sponge and soapy water.

REQUIRED TOOLS:
17mm Socket Wrench
3/4” Wrench

14. Connect and tighten shorter supply hoses onto diverter-tee. Use open end wrench.
15. Next, install the sidespray assembly by installing rubber gasket & escutcheon 

flange along with base shank into 1-3/8” mounting hole.

16. From underneath the sink, install plastic mounting nut onto base shank until fully 

tightened.

17. Set sidespray into place. Insert spray hose into base.

18. Install and tighten end of hose onto diverter (M15 fitting).
19. Connect the inlet supply lines to the angle stop wall valves. Do not allow the 

supply tubes to twist or bend sharply.

20. Open faucet handle - cold side first - by turning handle clockwise. Let the faucet 

run on cold for 15 to 30 seconds.

21. Turn off cold side handle.
22. Open faucet handle - hot side second - by turning handle counter-clockwise. Let the 

faucet run on hot for 15 to 30 seconds.

23. Open both faucet handles. Let the faucet run for 15 to 30 seconds.
24. Pull sidespray hose out of its base and point the open end towards the sink drain.  
25. Let the sidespray run for 15 to 30 seconds. When sidespray is depressed, ensure 

spout turns off and turns back on when spray is not in use.

26. Turn faucet off. 
27. Check / test for leaks under the cabinet.

Banjo Fitting

Sidespray Hose

Summary of Contents for FF6000

Page 1: ... or scratches improper installation abnormal usage negligence or damage caused by improper maintenance or cleaning Normal wear of parts is excluded from the warranty Damage caused by impurities or acts beyond our control are not covered Any product or part which has been repaired or altered in any manner outside of Franke s factory unless previously authorized in writing by Franke will void warran...

Page 2: ... NSF 61 UPC and C UPC requirements TECHNICAL DATA SPARE REPLACEMENT PARTS LIST FF7000 1 Cartridge Cold Lead Free 2 Cartridge Hot Lead Free 3 Banjo Diverting Locknut 4 Aerator 2 2 GPM For Aerator 1 5 GPM 10560 Handle Standard Lever Lalingua Handle Decorative Lalingua Tee Body Diverter Sidespray Head Grip Diverting Hose Banjo Fitting Valve Body Connection Hoses Locknut for Faucet 10210 10211 10418 1...

Page 3: ...s The faucet will not sit secure when sitting on such 5 Detach hose fittings from tee body temporarily remove locknut from diverting side 6 Slide banjo fitting down from its location 7 Unscrew plastic mounting nuts from the faucet shanks 9 Assure that the handles and spout are properly aligned in correct positions spout should swivel face forward into sink and handles should point outward parallel...

Page 4: ...4 Wrench 14 Connect and tighten shorter supply hoses onto diverter tee Use open end wrench 15 Next install the sidespray assembly by installing rubber gasket escutcheon flange along with base shank into 1 3 8 mounting hole 16 From underneath the sink install plastic mounting nut onto base shank until fully tightened 17 Set sidespray into place Insert spray hose into base 18 Install and tighten end...