EN
9
9
Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr located on
the hood body mounting points.
• Hook the hood body onto the screws 12a.
• Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body.
• If necessary, it is possible to fasten the hood to the wall using more
screws with wall plugs, which can be positioned from inside the hood
canopy.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.
To install a ø 150
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
To install a ø 120
• To install a ø 120 mm air exhaust connection, insert the
reducer flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
• Remove any activated charcoal filters.
9
ø 120
ø 150
10
10
AIR OUTLET – RECIRCULATION VERSION
• Unfasten the 2 screws fixing the upper bracket 7.2.1.
• Fasten the air outlet connector 15 in its place, using the 2
screws removed as above.
• Join the Connector 15 to the Hood canopy outlet using a rigid
or flexible pipe ø150 mm, selection of which is at the
discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has been
fitted.
Summary of Contents for FCR 625 TC
Page 67: ......