Step 8 : Checking the TMV Temperature
Step 9 : TMV Temperature Calibration and Setup
Ensure water supply is isolated and power running to the tap is
turned on.
Using a 6mm slotted screw driver the cold water supply is
activated by turning the integrated water isolation valve 90º
counter clockwise (Fig 7.1). Follow the same procedure for the
hot supply.
Fig 7
Fig 7.1
Fig 8
Hold a thermometer under the outlet (Fig8) of the tap, this
should start the flow of water from the tap allow the tap to
run and the water to get up to temperature and settle (Fig 8).
The temperature should be set at 41˚C.
If the temperature is outside the range 40-42˚C the TMV
should be calibrated, as per Step 9.
Step 6 :
Continued...
Using a 2.5mm Allen key fit retainer screw (Fig. 6 and 6.1).
Page
4
Page
5
Isolate the hot and cold water supply.
Carefully remove screw cover, retainer screw and penny washer,
only (Fig 9).
Remove the spindle plug (in middle of spindle head) (Fig 10).
Fig 9
Fig 10
Fig 6.1
Fig 6
Fit main tap body to wall spigot (Fig. 5). Ensure body is fully
located over the spigot.
Fig 5.1 shows the body correctly located whereas the body has
not been fully engaged in Fig 5.2.
Fig 5.1
Fig 5.2
Step 7:
Activating the water & power supply
SCREW COVER
RETAINER SCREW
PENNY WASHER
TOP CAP
LIMIT RING
CARTRIDGE RETAINER NUT
SPINDLE PLUG
Fig 5