of 16
8
Risk of burning or scalding to person(s) in the vicinity of the unit
during cool down or calibration cycle if the dranin lines are not
secured properly during installation.
Hot water and steam are released under pressure during the cleaning cycle.
Ensure drain lines are securely anchored in per local, state, and national building and plumbing codes.
Installation
NOTE:
Use only 6mm high temperature tube supplied with BKON unit.
NOTE:
Do not connect tower drain to WVSC drain. Both should empty into the store drain.
NOTE:
Dashed lines in diagram represent drain lines.
WARNING
Filtered
Water
Supply
Store
Drain
1
5
2
6
3
7
4
8
Connection Diagram
1
Hot Water from WVSC to
Tower
2
Cold Water from WVSC to
Tower
3
Air from WVSC to Tower
4
Tower Drain to Store Drain
5
WVSC Drain to Store Drain
6
Tower Drain Pan to Store Drain
7
Communication Cable from
Tower to WVSC
8
Water Supply