ZMI
_001_
2030
0204
53-A
Q
CT0073
_#SE
N
_#AQ
U
_#V
2.f
m
- 18 -
30. Troubleshooting
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Water volume regulator closed
➯
Open it
– Power supply interrupted
➯
Restore it
– Solenoid valve cartridge faulty
➯
Replace it
– Sensor faulty
➯
Replace it
– Dirty filters/non-return valves
➯
Clean and
replace if
necessary
Water flows
continuously
– Solenoid valve cartridge faulty
➯
Replace it
– Flow rate regulator in shower head
blocked with scale
➯
Clean and
replace if
necessary
Flow time too short or
too long
– Incorrect flow time setting
➯
Set it
– Shower head blocked with scale
➯
Cleaning
Water too hot
– Scald protection set incorrectly
➯
Set it
– Thermal element faulty
➯
Replace it
Water too cold
– Scald protection set incorrectly
➯
Set it
– Hot water flow blocked
➯
Open it
– Dirty filters/non-return valves
➯
Clean and
replace if
necessary
– Hot water supply pressure too low
➯
Check it
– Hot water temperature too low
➯
Increase it
– Thermal element faulty
➯
Replace it
Water volume too low
– Water volume regulator not fully open
➯
Open it
– Shower head blocked with scale
➯
Clean it
– Dirty filters/non-return valves
➯
Clean and
replace if
necessary
– Supply pressure too low
➯
Check it
Thermostat controls
unevenly
– Flow rate regulator in shower head
blocked with scale
➯
Clean and
replace if
necessary
– Thermal element dirty
➯
Clean it