2. Tap Menu

Run on time

 – How long the faucet will run when your hands are moved away from the sensor. 

Range

 - The distance away from the sensor that will trigger operation.

Wave On-off

 – Change the behavior of the tap so that a wave on will start the water 

running.A second activation will turn off the water. This is primarily for remotely installed 

sensors. 

Anti-Vandal Time

 - In the event of a blocked or vandalized sensor, this is the time that 

the sink will run until automatically shutting off. 

Automatic Purge

- Time between automatic run-times to help combat stagnant water in 

the pipes.

Lock Outs

 – System can be locked out from use after a pre-set number of operations. 

3. Ozone Control Menu

The ozone control menu is for preventative maintenance and data logging for Medi-flo 

and Ozo-flo.

Ozone Count

 – the total time in hours the ozone generator has run. 

Valve Time

 – The number of activations that the solenoid valve has been triggered

Wash Data

 – The system will keep track of average wash and rinse times which can be 

accessed via USB cable. (see Data Logging step for details.

NOTE: Each parameter (ozone count, valve timer and wash data) can be reset individually 

or all at once. To reset, point the programmer at the sensor, select the desired function to 

reset and press OK. Reset accordingly, as items are replaced or maintained to track usage.

Firmware Updates

To update the firmware on your Hand held Programmer, follow the steps below:

1. Plug the programmer into your PC via USB and press OK to enter “mass storage mode”
2. Open programmer files on your PC and drag new software file into the first file’s folder.
3. EJECT, then unplug the programmer.
4. Turn the programmer on.
5. Scroll to System Menu, and scroll down to “Firmware Update”, then press OK.
6. Select new firmware version and press OK, then wait for screen to load.
7. Follow the on-screen instructions to complete.
                                 

2030040792 | 

 01/19

4

1

Navigation buttons (x4)

2

OK

3

On/Off

4

Receive

5

Send

6

Switch cover

7

Isolation switch

8

USB / charging port

9

Screen legend for tap menu only 

T= No. of Operations 

P= No. of Purges 

R= Total Run Time (mins)

3

1

2

7

8

4

5

6

T=00000       P=0000

     R=00000

9

Programmer layout & legend

The use of this crossed out wheeled bin logo indicates that this product needs 

to be disposed of separately to any other household waste.

Legend

Summary of Contents for AC01-005

Page 1: ...total dissolved solids V Number of actuations the solenoid valve has made O Total time in hours the ozone generator has run AC01 005 2030040792 01 19 2 Step 2 Data Logging a To upload data from the programmer ensure it is switched ON then connect the pro grammer to your computer via USB b When prompted press OK on programmer keypad to enter mass storage mode c Find USB drive in My Computer area d ...

Page 2: ... number of activations that the solenoid valve has been triggered Wash Data The system will keep track of average wash and rinse times which can be accessed via USB cable see Data Logging step for details NOTE Each parameter ozone count valve timer and wash data can be reset individually or all at once To reset point the programmer at the sensor select the desired function to reset and press OK Re...

Page 3: ...la coche verte s affiche Le capteur est maintenant réglé selon les nouveaux paramètres AC01 005 2030040792 01 19 6 IMPORTANT une fois que vous avez programmé le capteur attendez au moins 30 sec ondes avant utilisation Cela permet de réétalonner le capteur En cas de non respect de cette durée minimale le capteur risque de se verrouiller ou de s activer par erreur Légende écran menu Medi flo TDS MDT...

Page 4: ...e le système hors service après un certain nombre préétabli d activations 3 Menu commande ozone Le menu commande ozone correspond à l entretien préventif et l enregistrement des données ayant trait à Medi flo et Ozo flo Durée ozone Durée totale de fonctionnement en heures du générateur d ozone Activation robinet Il s agit du nombre d activations du robinet déclenchées par l électrovanne Données su...

Reviews: