9
18
-05.
984
b-GB
.f
m
14. Adjustments
Various adjustments can be made using the free software
(FAR-Order-No. 4897 00 00).
☞
The shower remains locked for 2 min after each shower procedure. This time of
occupancy can not be changed.
Adjustable Parameters
• Payment time:
– Time during which the coins or tokens must be inserted into the counter. The
shower is enabled after this time has elapsed.
Additional coins are not counted.
– Adjustable range: 1-30 sec
– Factory setting: 10 sec
• Delivery unit:
– Duration of media deliver per paid unit. Up to 30 coins can be inserted.
– Adjustable range: 1-510 sec
– Factory setting: 3 min
• Expiration time:
– Time until the credit expires when not used. The shower is enabled for
payment.
– Adjustable range: 1-30 min
– Factory setting: 5 min
15. Maintenance and Servicing
• The coin-activated switch does not require special maintenance.
• Use a moist microfibre cloth to remove any external soiling on the housing.
16. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Fault
Cause
Remedy
Water does not flow
– Voltage supply interrupted
➯
Restore it
– Coin-activated switch faulty
➯
Replace it
Water flows
continuously
– Coin-activated switch faulty
➯
Replace it
Summary of Contents for 7612982130793