15. Fault correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our service department!!
Fault
Cause
Remedy
Water does not flow
– Water flow regulator closed
➯
Restore
– Functional part faulty
➯
Replace it
Water flows
continuously
– Functional part faulty
➯
Replace it
– Valve seat dirty
➯
Clean it
Water flow too weak
– Aerator calcified
➯
Clean it
– Supply pressure too low
➯
Check it
– Grit filter/return-flow inhibitor is
contaminated
➯
Clean it
– Water flow volume regulator not fully
opened
➯
Open it
Flow time too short or
too long
– Incorrect setting
➯
Adjust it
– Mesh washer contaminated
➯
Clean it
– Aerator calcified
➯
Clean it
– Functional part defective
➯
Replace it
Water is too hot
– Temperature limit is incorrectly set or
not set at all
➯
Adjust it
– Cold water is turned off
➯
Open it
– Return flow inhibitor in the cold
water connection is faulty
➯
Replace it
Water is too cold
– Return flow inhibitor in the cold
water connection is faulty
➯
Replace it
– Hot water is turned off
➯
Open it