21. Troubleshooting
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Water volume regulator closed
➯
Open it
– Functional element faulty
➯
Replace it
– Dirty filters/non-return valves
➯
Clean and replace
if necessary
Flow time too short or
too long
– Incorrect flow time setting
➯
Set it
Water flows continu-
ously
– Functional element faulty
➯
Replace it
– Flow rate regulator in shower head
blocked with scale
➯
Clean and replace
if necessary
Water too hot
– Scald protection set incorrectly
➯
Set it
– Thermal element faulty
➯
Replace it
Water too cold
– Scald protection set incorrectly
➯
Set it
– Hot water flow blocked
➯
Open it
– Dirty filters/non-return valves
➯
Clean and replace
if necessary
– Hot water supply pressure too low
➯
Check it
– Hot water temperature too low
➯
Increase it
– Thermal element faulty
➯
Replace it
Water volume too low
– Water volume regulator not fully
open
➯
Open it
– Shower head blocked with scale
➯
Clean it
– Dirty filters/non-return valves
➯
Clean and replace
if necessary
– Supply pressure too low
➯
Check it
Thermostat controls
unevenly
– Flow rate regulator in shower head
blocked with scale
➯
Clean and replace
if necessary
– Dirt in thermal element
➯
Clean it