8
ZMI
_001_
2000
110589
-AQ
M
XS00
02_#
SEN_#
AQU_#
V
1.
fm
Remove the fitting
For some maintenance tasks, the fitting must be removed.
14.1
Close the water supply.
14.2
Disconnect the fitting.
14.3
Remove the grub screw (c) from the fitting.
14.4
Remove the fitting (a), using the guide sockets (b).
15. Replacing the filters
15.1
15.2
Replace the filters (a).
☞
Important!
Note the installation position of the filters.
15.3
Reassemble in reverse order.
16. Replace the non-return valve
Warning!
All non-return valves must be replaced at once.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
☞
The non-return valve forms part of the guide socket (a).
16.1
16.2
Replace the guide socket (a).
16.3
Reassemble in reverse order.
17. Replace the aerator
17.1
Remove the aerator, using an open-ended wrench.
17.2
Replace the aerator.
18. Replace the functional element
18.1
Disassemble the pressure cap up to the temperature stop ring (see
☞
Important!
When removing the functional element, ensure that the cartridge (a) remains in the
fitting.
18.2
Replace the functional element (b).
18.3
Set the temperature limits (see