5
ZMI
_001_
2000
1037
93-A
Q
CT0025
_#SE
N
_#AQ
U
_#V
1.f
m
4. Important notes
• Installation, commissioning and maintenance are to be performed only by a
qualified expert in accordance with the provided instructions, legal requirements,
and the recognised engineering standards.
• All technical connection regulations specified by the local water and electricity
supply companies must be observed.
• The battery compartment with battery or power supply with extension cable must
be ordered separately (see Accessories,
Chapter 20
).
• All work must be carried out in a de-energised state.
• We reserve the right to make changes.
5. Application
AQUACONTACT - DN 15 shower fitting for wall mounting with electronic time control
for battery or mains operation. For connection to premixed hot water or cold water.
30 second flow time.
Installation kit with integrated hygiene flush (24h after last actuation, for 10s).
Functions which can be activated via reflection code on sensor: Activation/deacti-
vation of hygiene flush and cleaning switch-off (3 min.).
Additional functions via optional remote control
– Setting the flow and interval times
– Switch from time control to body reflection, maximum flow time of 300 seconds
– Program-controlled thermal disinfection with safety switch-off
6. Technical specifications
Minimum flow pressure:
1.0 bar
Recommended flow
pressure:
1-5 bar
Maximum operating
pressure:
10 bar
Calculation of flow rate:
0.20 l/s
Volumetric flow:
0.50 l/s at a flow pressure of 3 bar
Flow time at 38°C
1–50 s adjustable on shower head 0.20 l/s
Operating voltage:
6 VDC
Power consumption:
1.5 W
Protection class: