- 7 -
ZMI
_001_
2000
1013
40-A
Q
UA40
1_#S
EN_#A
QU_#V
5.
fm
Install the electrical T-distributor
☞
Important!
The components of the electrical T-distributor may only be installed after the power
has been switched off.
☞
Recommended system cable see
, accessories.
When using cables other than the system cable, pay attention to the different colour
code. The outer diameter must not exceed 7.5 mm.
11.11
Remove the sleeving (a) of the system cable (approx. 40 mm).
11.12
Push the union nut (c) onto the system cable (b) up to the limit stop.
☞
The various wire guides are marked with numbers 1 to 4.
A: Union nut
B: FAR-Best.-Nr. 2000104272
FAR-Best.-Nr. 2000104274
FAR-Best.-Nr. 2000100801
FAR-Best.-Nr. 2000100852
11.13
Push the wires (d) into the wire guides (e) according to their colours.
11.14
Cut off the projecting wire ends flush, i.e. without protrusions.
11.15
Push the union nut (c) onto the electrical T-distributor (f) and tighten it to the required
torque (1.2 Nm).
Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
☞
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.
11.16
Attach the electronic module to the pressure cap (simplified view).
11.17
Connect the wires between the electronic module, the solenoid valve cartridge and
the optical sensor.
A: Solenoid valve cartridge
B: Sensor connector (not used)
C: Optical sensor
D: Electrical T-distributor system cable (power)
E: Electronic module
A
B
1
brown
red
2
white
white
3
blue
blue
4
black
black