![Franke 2000101328 Installation And Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/franke/2000101328/2000101328_installation-and-operating-instructions-manual_2327113005.webp)
- 5 -
ZMI
_001_
2000
1013
28-ZAQ
U
A03
2_#S
EN_#A
QU_#V
2.f
m
8. Assembly Instructions
8.1
Remove the cover plate or the shower panel.
☞
For further details please consult the Installation and Operating Instructions for the
fitting.
8.2
Use an Allen key to close the water volume regulators.
a: closed
b: open
8.3
Trigger the valve.
8.4
Disconnect the line connection between the solenoid valve and the electronic
module.
8.5
Loosen the nuts (c).
8.6
Remove the solenoid valve and the seals.
8.7
Install the new seals (d).
8.8
Insert the new solenoid valve (e).
8.9
Tighten the nuts (c).
8.10
Disconnect the line between the solenoid valve (e) and the electronic module (f).
☞
Insert an adapter (g) if necessary.
☞
The screw length is dependent on the height of the plug connector (h).
8.11
Remount the cover plate or the shower panel.