The connection pipe and any draught stabiliser must
have access for cleaning.
-
The spigot should be connected to a minimum of 125
mm flue system and in that case the appliance is
capable of burning untreated wood and recommended
solid fuels.
2.6. Mounting the tray
Figure 6
To avoid damage during transport, the tray has been
stored behind the main door. Fix the tray on the
appliance.
-
Centre on tab “
A
” and lower into place.
2.7. Pre-utilisation check
-
Check that the glass is not damaged.
-
Check that the smoke passages are not obstructed by
packaging or removable parts.
-
Check that the seals of the smoke-line are in good
condition.
-
Check that the doors close correctly.
-
Check that all removable parts are correctly installed.
(side walls, flue baffle, grates, etc.)
Note :
if it acts of a ceramics braid, it is consumable and
thus brought to be changed by the user
2.8. Door closing pressure
Figure 7
: The closing latch rotates around a pressure
screw positioned cam.
-
Remove gently the ceramics rope
-
Loosen pressure screw
1
.
-
Turn cam
2
to desired position.
-
Tighten pressure screw
1
.
6
Technical manual “986”
“Savoy” - ref. 134 08 05
Installation instructions
!
"
!
$
"
#
Figure 5 - Chimney connections
1
- Chimney
2
- Funnel-shape
fireproof material
3
- Non combustible
register plate
4
- Cleaning access
door
5
- Liner
6
- Non combustible
register plate and
ventilated air
A
Figure 6 - Mounting the tray
1
2
Figure 7 - Door closing pressure
1
- Pressure
screw
2
- Cam