This appliance is meant to burn wood and smokeless fuels safely
WARNING
Incorrectly installed, this appliance can be dangerous and possibly cause serious accidents.
We recommend that you engage the services of a professional engineer for its installation
and the regular maintenance requirements.
1. Product information
1.1. Package
•
1 package : Stove complete.
1.2. General characteristics
Reference . . . . . . . . . . . . . . . .
134 08 05
FUEL : WOOD
Chimney draught required . . . . . . Pa
12
Volume heated . . . . . . . . . . . . m
3
280
Usable firebox dimensions
- width . . . . . . . . . . . . . . . . mm
450
- depth . . . . . . . . . . . . . . . . mm
240
- height . . . . . . . . . . . . . . . . mm
365
Log dimensions
- Lenght maxi . . . . . . . . . . . . . cm
40
Ash pan capacity . . . . . . . . . . litres
3
Net weight . . . . . . . . . . . . . . . kg
100
Flue gas temperature . . . . . . . . . °C
341
Nominal output . . . . . . . . . . . . kW
7,7
Efficiency . . . . . . . . . . . . . . . . %
72,6
Co (13% O
2
) . . . . . . . . . . . . . . %
0,42
Flue gas mass flow . . . . . . . . . . g/s
7
Fuel rate . . . . . . . . . . . . . . . kg/h
2,4
Refuelling interval . . . . . . . . . . mn
102
FUEL : ANTHRACITE (SMOKELESS FUELS)
Tested with fuel brand name “phurnacite” entering in
category A, table B2 frpm the standard EN 13240.
Nominal heat output . . . . . . . . . KW
6,4
Chimney draught required . . . . . . Pa
18
Flue gas temperature . . . . . . . . . °C
165
Efficiency . . . . . . . . . . . . . . . . %
73
Co (13% O2) . . . . . . . . . . . . . . %
0,5
Fuel rate . . . . . . . . . . . . . . . kg/h
0,8
Refuelling interval . . . . . . . . . . mn
132
1.3. Description
•
Multifuel stove
in conformity with DIN EN 13240 :
2005-10
•
Intermittent-burning heating appliance wood and
smokeless fuels.
•
Fuel burnt on grate
•
Enclosed combustion chamber with refractory brick
walls.
•
Removable appliance, to be installed near a wall.
•
Detachable flue spigot for rear or top chimney
connection.
•
Detachable top for easy handling and cleaning (rear
smoke exit only).
•
Adjustable air controls for controlling the burning rate.
•
Spin wheel for lighting.
•
Large ash-pan.
1.4. Principle of
operation
The
appliance
is
designed for operation
with the door closed.
Heat is mainly diffused by
radiation, through the
window and body of the
appliance.
Combustion occurs on
the grate, with draught
entry through the top of
the combustion chamber
when using wood and
under the grate when
using smokeless fuels.
Technical manual “986”
3
“Savoy” - ref. 134 08 05
Product information
6 6 0
1 3 4
5 2 0
4 0 9
5 3 5
Ø 1 2 5
Ø 1 3 9
3 6 0
Figure 1 - Dimensions in mm