FRANCO BELGE Savoy Classic 134 08 05 Technical Manual Download Page 1

Description of the appliance

Installation instructions

Operating instructions

Spare parts

Warranty certificate

Document n° 986-11 ~ 03/12/2007

STAUB FONDERIE

Head Office Address

2, rue Saint Gilles

68230 TURCKHEIM

RCS Colmar

SIREN 444 881 953

Address

Administration and manufacturing

BP 73

59660 MERVILLE (FRANCE)

Telephone : 00 333 28 43 43 00

Fax : 00 333 28 43 43 99

Subject to modifications.

SAVOY Classic

 

Multifuel stove

Model : 134 08 05

DIN EN 13240 : 2005-10

Net output : 7,7 kW (Wood)

Net output : 6,4 kW (Smokeless fuels)

Technical manual

to be saved

by the user

for future reference

SARL with the capital of 10 000 000 €

Summary of Contents for Savoy Classic 134 08 05

Page 1: ...CKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 00 Fax 00 333 28 43 43 99 Subject to modifications SAVOY Classic Mult...

Page 2: ...r use with wood p 9 Instructions for use with solid fuel p 9 Cleaning p 9 Maintenance of the Chimney p 9 Maintenance of the stove body p 9 Recommendations p 9 Trouble Shooting p 10 Spare parts p 11 FR...

Page 3: ...heat output KW 6 4 Chimney draught required Pa 18 Flue gas temperature C 165 Efficiency 73 Co 13 O2 0 5 Fuel rate kg h 0 8 Refuelling interval mn 132 1 3 Description Multifuel stove in conformity wit...

Page 4: ...flue pipe there must be a clearance A of at least three times its diameter B from any combustible materials If the appliance has to be located in an opening this distance must be extended to a minimum...

Page 5: ...retainer fuel fig 8 p 7 the two side bricks and the flue baffle fig 9 p 7 Remove the rear heat shield and remove the cut out on it Remove the blanking plate 3 and the clamp 4 and refit in the top ens...

Page 6: ...re in good condition Check that the doors close correctly Check that all removable parts are correctly installed side walls flue baffle grates etc Note if it acts of a ceramics braid it is consumable...

Page 7: ...First remove the retainer grate fig 8 A fig 9 the two side walls B fig 9 and the flue baffle C fig 9 Refit the parts in the reverse order DO NOT OPEN THE DOOR OF THE APPLIANCE OR AIR INLET UNDER ANY...

Page 8: ...of old and or infirm people 3 1 Fuel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a...

Page 9: ...ED TO FLOW FROM THE ASH PIT AREA THROUGH THE GRATE AND THROUGH THE FUEL IF THE GRATE OR ASH PAN ARE CONGESTED THE PERFORMANCE WILL BE EFFECTED If burning solid fuel always empty the ash pan at least o...

Page 10: ...quality wood Do not continuously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is i...

Page 11: ...lap A B C D E 01 17 300127 EF Leg A 04 17 300128 MP Leg B 04 17 300128 RH Leg C 04 17 300128 MK Leg D 04 17 300128 RP Leg E 04 18 300481 EF Base A B C D E 01 19 301526 EF Door lock A 01 19 301526 MP D...

Page 12: ...ref 134 08 05 Spare parts 4 2 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 2 3 8 8 3 2 1 7 1 7 1 7 4 0 4 1...

Page 13: ...01 33 327903 RH Ash tray C 01 33 327903 MK Ash tray D 01 33 327903 RP Ash tray E 01 34 331104 EF Main door A 01 34 331104 MP Main door B 01 34 331104 RH Main door C 01 34 331104 MK Main door D 01 34 3...

Page 14: ...ombustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact with high te...

Reviews: