FRANCO BELGE Bourgogne Technical Manual Download Page 2

2

Technical manual “1091”

“Bourgogne” ref. : 174 10 56

CONTENTS

Description of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 3

Description . . . . . . . . . . . . . . . . P. 3
Package. . . . . . . . . . . . . . . . . . P. 3
Optional equipment . . . . . . . . . . . P. 3

Specifications. . . . . . . . . . . . . . . P. 3
Operating principle . . . . . . . . . . . . P. 4

Installation instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 5

Warning to the user . . . . . . . . . . . P. 5
Location of the unit. . . . . . . . . . . . P. 5
Chimney . . . . . . . . . . . . . . . . . P. 5
Smoke exit . . . . . . . . . . . . . . . . P. 6
Chimney connector. . . . . . . . . . . . P. 6
Levelling . . . . . . . . . . . . . . . . . P. 6
External / remote tank . . . . . . . . . . P. 6

Pre-utilization check . . . . . . . . . . . P. 7
Oil flows adjustment . . . . . . . . . . . P. 7
Mounting the tray. . . . . . . . . . . . . P. 8
Chimney draught . . . . . . . . . . . . . P. 8
Maintenance of the Chimney . . . . . . P. 8
Fitting the “visioflamme” (optional) . . . P. 8

Instructions for user. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 9

Fuel . . . . . . . . . . . . . . . . . . . . P. 9
Lighting . . . . . . . . . . . . . . . . . . P. 9
Operating procedure . . . . . . . . . . . P. 9
Shutting down . . . . . . . . . . . . . . P. 9

Recommendations . . . . . . . . . . . P. 10
Maintenance of the stove. . . . . . . . P. 10
Removing the burner . . . . . . . . . . P. 10
Trouble shooting . . . . . . . . . . . . P. 11

Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 12

FRANCO BELGE congratulates you on your choice.

FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the

quality of its appliances and is committed to meet its customers’ needs.

FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices,

uses state-of-the-art technologies

to design and manufacture its whole range of products.

This document contains instructions on how to install your appliance and make full use of

its functions, both for your comfort and safety.

Summary of Contents for Bourgogne

Page 1: ...e Ref 174 10 56 NF EN 1 Technical manual to be saved by the user for future reference STAUB FONDERIE SARL with the capital of 6 359 540 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colma...

Page 2: ...structions for user P 9 Fuel P 9 Lighting P 9 Operating procedure P 9 Shutting down P 9 Recommendations P 10 Maintenance of the stove P 10 Removing the burner P 10 Trouble shooting P 11 Spare parts P...

Page 3: ...3 Optional equipment 1 package Visioflamme mirrors P 174 10 53 1 package Glow plug ignitor 1 package Coals kit FC 0802 1 4 Specifications Model 174 10 56 Nominal Heat Output kW 10 Oil consumption at m...

Page 4: ...feed line there is a de scaling lever The de scaling lever can be operated to keep the inlet pipe clear of carbon build up The stove float regulator contains a filter to trap impurities A safety lever...

Page 5: ...d with combustible material Otherwise it must be necessary to install a non combustible protection Position the unit to comply with the minimum clearances to combustible material figure 4 2 3 Chimney...

Page 6: ...the flue spigot and be situated as distant as possible from the flue connection of the appliance The join between the connection pipe and the stovepipe and the flue must be leak tight The connection...

Page 7: ...of the burner and the catalyser body must be glowing red hot If the flame is too small the stove will soot up quickly increase the flame by turning the setting screw rep 2 clockwise If the flame is to...

Page 8: ...t will be made with the barometric damper rep 1 fig 9 located at the back of the stove 2 12 Maintenance of the Chimney Chimney condition should be checked at least once per year If the appliance is re...

Page 9: ...eat approximately 30 to 45 sec Turn dial to 1 position 2b Allow 10 to 15 minutes for oil fire and draught to stabilize The catalyser or the ring should glow red before adjusting the control knob to a...

Page 10: ...and to change the joint of the de scaling lever rep A fig 15 code 142889 by a professional installer To clean the filter of the float regulator Set the regulation knob in closed position 0 Turn off t...

Page 11: ...r contains excess fuel Adjust control knob to minimum speed If problem persists call your installer Fire smokes Soot build up noticed Flame imbalance Insufficient air supply Increase fresh air supply...

Page 12: ...276231 Reflector A B 01 31 300122 77 Leg A 04 31 300122 EF Leg B 04 32 300472 77 Base A 01 32 300472 EF Base B 01 33 301515 66 Door lock A B 01 34 303301 76 Bearing A 01 34 303301 EF Bearing B 01 35...

Page 13: ...1 6 2 0 2 4 4 2 1 7 1 8 3 5 4 8 2 2 4 3 6 3 0 4 1 1 3 2 7 3 1 3 2 4 3 1 3 3 3 5 9 1 0 1 8 5 4 0 2 6 1 1 2 1 3 9 4 4 4 9 5 0 5 3 5 1 4 7 2 8 3 8 4 5 3 4 3 7 4 6 4 5 5 5 7 5 4 5 9 5 8 5 2 2 9 5 5 2 3 3...

Page 14: ...tion of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in cont...