2.9. Levelling
•
It is essential to ensure that the appliance sits level on
the floor. Adjust the levelling feet (# 7, fig. 16, p. 9).
•
Use a spirit level across the burner pot to check the
level (fig. 10).
2.10. Oil flow adjustment
The float regulator has been adjusted at the factory and
should not need further adjustment. If the burner does
not work correctly, check possible causes before
readjusting the settings :
-
Chimney draught
-
Fresh air inlet
-
Oil supply.
Low setting
(Refer to fig. 11 , # 4) :
-
set the regulating knob on “1" and let the burner run for
a few minutes. The flame must completely cover the
bottom of the burner and the catalyser body must be
glowing red hot.
-
if the flame is too small, the stove will soot up quickly ;
increase the flame by turning the setting screw (# 4)
clockwise.
-
if the flame is too high, reduce the flame by turning the
setting screw (# 4) counter clockwise.
High setting
(Refer to Fig. 11 , # 5) :
-
set the regulating knob on “6" and let the burner run for
a few moments. The flame must be shaped like a cone
and reach the upper part of the door.
-
if the flame is too low, increase by turning the set
screw anti-clock-wise.
-
if the flame is too high, reduce by turning the set screw
clockwise.
Technical manual “954”
7
“Le Beffroi” ref. 174 10 54
Installation instructions
1
2
3
Figure 9 - Top panel assembly
1
- Enamel top plate
2
- Natural stone
3
- Ceramic rope
Fig. 10- Levelling
Figure 11 - Operating devices
1
2
3
4
5
6
7
1
- Adjustment of the draught regulator.
2
- Safety lever.
3
- Access to regulator filter.
4
- Adjustment screw for minimum setting.
5
- Adjustment screw for maximum setting.
6
- Safety pressure door
7
- Vent-pipe (optional).