Please note - Very important
: The adjustments of the
float regulator are very sensitive. The hight and the low
setting screws must never be turned more than a 1/4 of
a turn at a time in any direction from their initial setting.
When making any adjustments, allow 3 to 5 minutes
between adjustments to allow burner to stabilize to
previous adjustment before proceeding, if necessary.
2.11. Chimney draught
Once the stove has been properly installed, the
chimney draught must be checked.
The adjustment of the draught will be made with the
barometric damper located at the back of the stove
(# 1, fig. 11).
The reading of the draught must be done once the unit
is hot (minimum 30 minutes of use).
Refer to the specifications p. 3 for minimum draught
requirement on mini setting and on maxi setting.
2.12. Door closing pressure
Figure 13
The closing latch rotates around a pressure screw
positioned cam.
-
Loosen pressure screw
1
.
-
Turn cam
2
to desired position.
-
Tighten pressure screw
1
.
2.13. Pre-utilisation check
Check the condition of the filler seals, that the door
closes correctly, that the window is not damaged, that
the smoke passages are not obstructed by packaging
or removable parts. All removable parts, fuel retainer,
baffle (fig.15), must be correctly installed.
2.14. Mounting mirrors (Optional)
Open the window and position the glasses in the
reflector runner (# 4, fig. 16, p. 9).
2.15. Maintenance of the Chimney
Chimney and chimney connector should be inspected
at least once every three months during the heating
season to determine if a soot build up has occurred. If
soot has accumulated, it should be removed to reduce
the risk of a chimney fire.
8
Technical manual “954”
“Le Beffroi” ref. 174 10 54
Installation instructions
Figure 12 - Draught control
Figure 13 - Door closing pressure
2
1
!
"
Figure 14 - Removing the flue baffle
!
"
Figure 15 - Fitting the flue baffle
1
- Pressure screw
2
- Cam