background image

§

Warranty certificate

§

§

Legal warranty

Our products are guaranteed for twelve months against any
defect, flaw or imperfection. During this time, all parts judged
defective by our Warranty control department may be repla-
ced in our workshops. Incidental costs of transportation and
packing payable by the buyer.
Some parts or components have a longer warranty period :
- Cast-iron shell of boiler : 3 years
- Steel shell of boiler : 3 years
- Removable or independent stainless steel hot water cylin-
der : 5 years
- Independent enamelled steel hot water cylinder : 3 years

- Incorporated circulating pump : 2 years.

§

Terms of the warranty

This warranty is only valid if :
- The unit has been installed and checked by a professional
installer before operating,
- All installation and adjustment instructions listed in the

technical manual supplied with the unit have been followed,
- All operation and maintenance instructions have been
followed.

This warranty does not cover

:

- Lamps, fuses, spark plugs, cast iron parts directly in con-
tact  with burning coal  and wood, firebricks, flue baffles,
glasses .
- Any damage resulting from the use of fuel not recommen-
ded in our instructions ;
- Parts which are damaged by external causes such as
unadapted chimneys, thunderstorms, damp, faulty pressure
or fail in pressure, thermic anomalies, explosions, etc...
- Electrical parts which are deteriorated by any connection
or use on a supply circuit with voltage within 10% of the
indicted voltage (230 V in EU).

Material subject to modifications without prior notice. This
manual does not engage the responsibility of
FRANCO BELGE.

*

Name and address of the installer :

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

(

Telephone : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

*

Name and address of the customer :

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Date of installation :

__ __ / __ __ /__ __ __ __

Model of the appliance :

Color :

Serial number :

___ ___ ___ ___ ___ ___

• This certificate has to be completed and kept carefully.

In case of claims, send a copy of this to :

Les Fonderies Franco-Belges, rue Orphée Variscotte, 59660 MERVILLE, FRANCE.

D

ocument

97

9-3

E

N

~

28

/08

/20

00

q

174 05 05

q

Y

q

J

q

K

q

C

Summary of Contents for 174 05 05

Page 1: ...es Franco Belges 59660 MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Belfort Oil fired stove Model 174 05 05 EN 1 CAN CSA approved ANSI UL approved...

Page 2: ...uctions 8 Fuel 8 Lighting procedure 8 Operating procedure 8 Shutting down 8 Maintenance of the stove 8 Recommendation 9 Trouble shooting 10 Spare parts 11 FRANCO BELGE congratulates you on your choice...

Page 3: ...TU hr 18 000 Oil consumption at maximum speed litre h 0 58 US gal hr 0 16 minimum speed litre h 0 17 US gal hr 0 045 Chimney draught required at maximum speed Pa 15 in w g 0 06 minimum speed Pa 8 in w...

Page 4: ...ernal factors 2 Installation instructions SAFETY NOTICE Read carefully all instructions before starting the installation If the stove is not properly instal led a house fire may result For your safety...

Page 5: ...the rear heat shield must not be remove in the case 2 5 Rear flue outlet Figure 7 Open the main door remove the ceramic coal grate with theirs coal 9 and 10 fig 4 p 4 and remove the internal baffle 4...

Page 6: ...pressure 300 mbar If the tank is lower than the stove a lift pump will have to be utilized A clearance of 6 15 cm must be maintained between the external remote tank and the stove 2 9 Levelling It is...

Page 7: ...than a 1 4 of a turn at a time in any direction from their initial setting When making any adjustments allow 3 to 5 minutes between adjustments to allow burner to stabilize to previous adjustment befo...

Page 8: ...djust to new setting If the burner stops during operating immediately turn off the control knob position 0 and wait until the burner is completely cool before repeating the lighting procedure 3 4 Shut...

Page 9: ...be considered as a defect but rather as a patina of the enamel which does not affect its quality nor its service ability 3 6 Recommendation The adjustment of the stove has been made at the factory and...

Page 10: ...oot build up noticed Flame imbalance Insufficient air supply Increase fresh air supply open door window add make up air supply Downdraught or blockage in chimney Check Chimney for Soot build up clean...

Page 11: ...Back panel Y J K C 01 32 209916 Protector Y J K C 01 33 222560 Flue baffle Y J K C 01 34 222611 Suppl flue baffle Y J K C 01 35 236708 94 Bracket Y J K C 01 36 239715 60 Carburettor support Y J K C 01...

Page 12: ...Document n 979 3 EN 28 08 2000 174 05 05 BELFORT Oil fired stove 12 Technical manual...

Page 13: ...d tool Y J K C 01 58 982629 Feed line regulator burner Y J K C 01 59 982630 Vent pipe Y J K C 01 60 818301 Grate Y J K C 01 61 307436 Fuel retainer Y J K C 01 62 109722 Ceramic coal 45x45x30 Y J K C 3...

Page 14: ...from the use of fuel not recommen ded in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalie...

Reviews: