3.7.
Trouble shooting
SYMPTOM
PROBLEM
-
TEST SOLUTION
Flames extinguish during
lighting.
¤ Very cold chimney. No draught
established.
-
- Leave door ajar until fire has caught.
- Check air supply in the room.
Fire extinguishes once
firestarter has burnt off.
¤ Fuel tank is empty.
-
- Fill tank.
¤ Fuel valve is closed.
-
- Open valve.
¤ Main regulator float not engaging.
-
- De-press the safety lever.
¤ Control knob is set on 0"
-
- Adjust control knob to 1".
Fire extinguishes during use.
¤ Fuel tank is empty.
-
- Fill tank.
¤ Insufficient draught.
-
- Call your installer.
Flame is excessively large,
smoky and sooty.
¤ Fuel adjustment made too quickly.
-
- Return control knob to 1"; wait for normal combustion.
(catalyser should glow red) Wait 5 to 15 minutes between
each adjustment.
Stove burns noisily,
extinguishes and relights itself.
¤ Burner contains excess fuel.
þ
-
- Adjust to lower setting. If problem persists call your
installer.
¤ Insufficient fuel.
-
- Check that the de-scaler, the float regulator filter and
burner pot are cleaned.
Fire smokes. Soot build up
noticed. Flame imbalance
¤ Insufficient air supply.
-
- Increase fresh air supply (open door, window; add make
up air supply).
¤ Downdraught or blockage in
chimney.
þ
-
- Check Chimney for Soot build up. clean if necessary.
- Ensure chimney height is sufficient and cap is not
affected by any nearby obstructions.
- Room is in negative pressure. Increase fresh air supply.
Check draught with draught meter and adjust if not to
requirements. See page 4.
¤ Oil flow is too low on 1 setting.
þ
-
- Adjust low flow rate while control is set on 1", call your
installer.
¤ Stove is not level. Flame
imbalance.
-
- Check level. Adjust if necessary.
¤ Catalyser not centered. Uneven
fuel distribution resulting in
secondary air shortage.
-
- Center catalyser assembly
¤ Insufficient fuel.
-
- Check that the de-scaler, the float regulator filter and
burner pot are cleaned.
¤ The draught regulator is blocked in
open position
þ
-
- Unlock the draught regulator.
- Check the float regulator adjustment and refit, if
necessary.
Coke build up noticed.
¤ Excessive air supply.
-
- Adjust draught.
þ : This sign means that you should
asked for a qualified engineer to do
the work.
Document n° 979-3 EN ~ 28/08/2000
174 05 05