3.7.

Trouble shooting

SYMPTOM

PROBLEM

-

TEST SOLUTION

Flames extinguish during

lighting.

¤ Very cold chimney. No draught
established.

-

- Leave door ajar until fire has caught.
- Check air supply in the room.

Fire extinguishes once

firestarter has burnt off.

¤ Fuel tank is empty.

-

- Fill tank.

¤ Fuel valve is closed.

-

- Open valve.

¤ Main regulator float not engaging.

-

- De-press the safety lever.

¤ Control knob is set on “0"

-

- Adjust control knob to ”1".

Fire extinguishes during use.

¤ Fuel tank is empty.

-

- Fill tank.

¤ Insufficient draught.

-

- Call your installer.

Flame is excessively large,

smoky and sooty.

¤ Fuel adjustment made too quickly.

-

- Return control knob to “1"; wait for normal combustion.
(catalyser should glow red) Wait 5 to 15 minutes between
each adjustment.

Stove burns noisily,

extinguishes and relights itself.

¤ Burner contains excess fuel.

þ

-

- Adjust to lower setting. If problem persists call your
installer.

¤ Insufficient fuel.

-

- Check that the de-scaler, the float regulator filter and
burner pot are cleaned.

Fire smokes. Soot build up

noticed. Flame imbalance

¤ Insufficient air supply.

-

- Increase fresh air supply (open door, window; add make
up air supply).

¤ Downdraught or blockage in
chimney.

þ

-

- Check Chimney for Soot build up. clean if necessary.
- Ensure chimney height is sufficient and cap is not
affected by any nearby obstructions.
- Room is in negative pressure. Increase fresh air supply.
Check draught with draught meter and adjust if not to
requirements. See page 4.

¤ Oil flow is too low on 1 setting.

þ

-

- Adjust low flow rate while control is set on “1", call your
installer.

¤ Stove is not level. Flame
imbalance.

-

- Check level. Adjust if necessary.

¤ Catalyser not centered. Uneven
fuel distribution resulting in
secondary air shortage.

-

- Center catalyser assembly

¤ Insufficient fuel.

-

- Check that the de-scaler, the float regulator filter and
burner pot are cleaned.

¤ The draught regulator is blocked in
open position

þ

-

- Unlock the draught regulator.
- Check the float regulator adjustment and refit, if
necessary.

Coke build up noticed.

¤ Excessive air supply.

-

- Adjust draught.

þ : This sign means that you should

asked for a qualified engineer to do

the work.

Document n° 979-3 EN ~ 28/08/2000

174 05 05

BELFORT

Oil fired stove

10

Technical manual

Summary of Contents for 174 05 05

Page 1: ...es Franco Belges 59660 MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Belfort Oil fired stove Model 174 05 05 EN 1 CAN CSA approved ANSI UL approved...

Page 2: ...uctions 8 Fuel 8 Lighting procedure 8 Operating procedure 8 Shutting down 8 Maintenance of the stove 8 Recommendation 9 Trouble shooting 10 Spare parts 11 FRANCO BELGE congratulates you on your choice...

Page 3: ...TU hr 18 000 Oil consumption at maximum speed litre h 0 58 US gal hr 0 16 minimum speed litre h 0 17 US gal hr 0 045 Chimney draught required at maximum speed Pa 15 in w g 0 06 minimum speed Pa 8 in w...

Page 4: ...ernal factors 2 Installation instructions SAFETY NOTICE Read carefully all instructions before starting the installation If the stove is not properly instal led a house fire may result For your safety...

Page 5: ...the rear heat shield must not be remove in the case 2 5 Rear flue outlet Figure 7 Open the main door remove the ceramic coal grate with theirs coal 9 and 10 fig 4 p 4 and remove the internal baffle 4...

Page 6: ...pressure 300 mbar If the tank is lower than the stove a lift pump will have to be utilized A clearance of 6 15 cm must be maintained between the external remote tank and the stove 2 9 Levelling It is...

Page 7: ...than a 1 4 of a turn at a time in any direction from their initial setting When making any adjustments allow 3 to 5 minutes between adjustments to allow burner to stabilize to previous adjustment befo...

Page 8: ...djust to new setting If the burner stops during operating immediately turn off the control knob position 0 and wait until the burner is completely cool before repeating the lighting procedure 3 4 Shut...

Page 9: ...be considered as a defect but rather as a patina of the enamel which does not affect its quality nor its service ability 3 6 Recommendation The adjustment of the stove has been made at the factory and...

Page 10: ...oot build up noticed Flame imbalance Insufficient air supply Increase fresh air supply open door window add make up air supply Downdraught or blockage in chimney Check Chimney for Soot build up clean...

Page 11: ...Back panel Y J K C 01 32 209916 Protector Y J K C 01 33 222560 Flue baffle Y J K C 01 34 222611 Suppl flue baffle Y J K C 01 35 236708 94 Bracket Y J K C 01 36 239715 60 Carburettor support Y J K C 01...

Page 12: ...Document n 979 3 EN 28 08 2000 174 05 05 BELFORT Oil fired stove 12 Technical manual...

Page 13: ...d tool Y J K C 01 58 982629 Feed line regulator burner Y J K C 01 59 982630 Vent pipe Y J K C 01 60 818301 Grate Y J K C 01 61 307436 Fuel retainer Y J K C 01 62 109722 Ceramic coal 45x45x30 Y J K C 3...

Page 14: ...from the use of fuel not recommen ded in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalie...

Reviews: