background image

Montfort Elegance

Montfort Mk2 EA

Wood burning stove

EN 13240

Model : 134 05 02

Nominal output : 5 kW

Description of the appliance

Installation instructions

Operating instructions

Spare parts

Warranty certificate

Document n°1300-5 - 20/03/2012

Technical manual

to be saved

by the user

for future reference

THIS APPLIANCE CAN BE INSTALLED IN UK SMOKE

CONTROL AREAS ONLY USING WOOD FUEL

Parc d’activités de la Verte Rue

Allée des Prêles

59270 BAILLEUL

Tél. : 03 28 40 32 50

Matériel sujet à modifications 

sans préavis.

Document non contractuel.

Summary of Contents for 134 05 02

Page 1: ...structions Spare parts Warranty certificate Document n 1300 5 20 03 2012 Technical manual to be saved by the user for future reference THIS APPLIANCE CAN BE INSTALLED IN UK SMOKE CONTROL AREAS ONLY US...

Page 2: ...9 Cleaning p 9 Maintenance of the chimney p 8 Maintenance of the stove p 8 Recommendations p 9 Trouble shooting p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality...

Page 3: ...he combustion chamber Reference 134 05 02 Nominal heat output kW 5 Chimney draft required Pa 12 Hearth dimensions width mm 335 depth mm 205 height mm 250 Log dimensions lenght maxi cm 20 Ash pan capac...

Page 4: ...lf of a minimum 50 cm2 Position of the unit For new installations select a central position within the house to provide a good heat distribution around the building The heat distribution towards the o...

Page 5: ...must not be shared with other appliances The chimney must be at least 4 5 m 15 ft high In case of a flat roof or when the roof gradient is lower than 15 the stack must be 1 2 m 4 feet high at least I...

Page 6: ...in transit Note all gaskets glass fiber ropes seals are consumable parts and must be changed on a regular basis by the user 2 9 Door closing pressure Figure 4 The closing latch rotates around a press...

Page 7: ...Montfort MK2 EA 1340502 Technical manual 1300 7 Figure 5 Replacing the parts Figure 5a Figure 5b Figure 5c Figure 5d...

Page 8: ...cause of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in the presence of children and also in the presence of old and...

Page 9: ...s door and add fuel Leave the primary air control open for a few minutes to allow the initial volatiles in the fuel to burn Adjust the primary air unlet to the desired position 3 4 Cleaning It is esse...

Page 10: ...ance must not be used with a flue serving several appliances Ensure the grate is free from any obstruction and riddles freely Warning It is quite normal for enamel surfaces to have a crackling appeare...

Page 11: ...uously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pr...

Page 12: ...A B C D E F 04 22 262612 Heat shield A B C D E F 01 23 265607 Knob A B C D E F 01 24 270412 Air control flap A B C D E F 01 25 300118 EF Leg A 04 25 300118 77 Leg B 04 25 300118 RJ Leg C 04 25 300118...

Page 13: ...1300 13 Montfort MK2 EA 1340502 Figure 8 Stove exploded view 36 48 20 30 41 1 24 35 3 50 43 52 9a 42 38 51 28 31 47 12 44 45 19 37 34 3 22 33 26 39 25 15 23 46 40 11 27 10 9b 8 21 21 49 13 4 32 5 5 1...

Page 14: ...upplementary plate A B C D E F 01 43 352168 EF Top plate A 01 43 352168 77 Top plate B 01 43 352168 RJ Top plate C 01 43 352168 RP Top plate D 01 43 352168 RH Top plate E 01 43 352168 MK Top plate F 0...

Page 15: ...Montfort MK2 EA 1340502 Technical manual 1300 15 Notes...

Page 16: ...stly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed com...

Reviews: