Installation Guideline
A typical installation and connection routine for the FH300 searchlight is as follows:
Referring to wiring diagram X4258, a supply is fed into the control gear enclosure, which then
provides a common feed to the control gear and the searchlight.
Cables required to be connected by the customer: -
5 core 1.5mm cable from the Control Gear to the Searchlight,
(Customer may need to provide a suitable junction box to this cable, 3 metres supplied).
The Mains cable to the Control Gear is to be supplied by the customer.
A typical installation and connection routine for the FH300 Remote Focus searchlight is as follows:
Referring to wiring diagram C20294, a supply is fed into the control gear enclosure, which then
provides a common feed to the control gear, control panel and searchlight.
Cables required to be connected by the customer: -
8 core 1.5mm cable from the Control Gear to the Searchlight
5 core 1.5mm cable from the Control Gear to the Control Panel.
(Customer may need to provide a suitable junction box to extend these two cables, 3 metres
supplied).
The Mains cable to the Control Gear is to be supplied by the customer.