INFORMATION FOR USERS 

 
 
 
 

For the purpose and effect of Directives 2002/95/CE, 2002/96/CE and 2003/108/CE, relative to the reduction of the use 
of hazardous substances in electrical and electronic appliances as well as the disposal of waste. 

 

The barred waste bin symbol indicates that the product must be collected separately from other waste at the end of its 
life.  
 
The user must  therefore take the appliance to  an approved collection point suitable for differential collection of electric 
and electronic waste. 
 

 

1.   SAFETY WARNINGS 

 
 
This dehumidifier must always be connected using earthed electrical plugs as required for all electrical appliances; FRAL 
Company declines any responsibility for any danger or damage whenever this norm is not complied with. 
 
Any intervention on the machine using any instrument must be carried out only by a qualified technician. 
 
When  the  machine  is  connected  to  the  power  socket,  it  must  be  in  a  vertical  position  and  moving  should  be  avoided.  
Moving  whilst  connected  to  power  could  cause  water  to  come  into  contact  with  electrical  parts.    It  is  therefore 
recommended to remove the plug from the socket before moving the dehumidifier.   
 
Correct Distance: this dehumidifier draws in the air from the back and lets out through the front side grill: therefore the 
back panel, which supports the air filter, must be kept at a minimum distance of 15cm from the wall. 
 
This dehumidifier has been designed and manufactured in compliance with the strictest safety rules. Therefore, pointed 
instruments (screw drivers, wool needles or similar) are not to be inserted into the grill or in the opening of the back panel 
when it is opened to remove the filter. 
 
The machine must not be cleaned using water. To clean the machine, use a wet cloth. Remember to disconnect the plug 
from the socket beforehand.  
 
The front panel should not be covered at anytime. 
  
The  filter  should  be  cleaned  periodically  (normally  every  month).    In  dusty  rooms  it  should  be  cleaned  more  often. 
Remember that when the filter is dirty, the air circulation and consequently, the machines performance is reduced. 

 

 

 
 
 

 

 

Summary of Contents for FDNF62

Page 1: ...FDNF62 DEHUMIDIFIER USER AND MAINTENANCE MANUAL FRAL AUSTRALASIA PO Box 5071 Port Macquarie New South Wales 2444 Australia ...

Page 2: ...on and moving should be avoided Moving whilst connected to power could cause water to come into contact with electrical parts It is therefore recommended to remove the plug from the socket before moving the dehumidifier Correct Distance this dehumidifier draws in the air from the back and lets out through the front side grill therefore the back panel which supports the air filter must be kept at a...

Page 3: ...uted by according to safety and electro magnetic compatibility to European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006 95 CE 12 12 2006 ELECTROMAGNETIC COMPATIBILITY EMC 2004 108 CE 15 12 2004 It is hereby certified that this Dehumidifier conforms to the IEC Regulations CEI EN 60335 2 40 CEI EN 55014 1 55014 2 The machine is built...

Page 4: ... Current at 35 C 95 rh standard ver 4 4 A Locked Rotor Current LRA 20 Air Flow 650 cm h Noise level at 3 meters 51 dB Refrigerant R134a Standard Defrosting Control System Electronic Hot Gas Defrosting Control System optional Electronic thermostat Water Tank Capacity 12 kg Continuous Drainage Pipe Connection 25mm Temperature Range standard version 7 35 C Temperature Range hot gas defrost system 1 3...

Page 5: ...RELAY 2 F1 3 ACL 5 LE2 6 LE1 4 LE3 1 ACN M1 ev M2 fan LEGEND 1 COMPRESSOR 2 FAN MOTOR 3 ELECTRONIC CARD 4 HUMIDISTAT ELECTRONIC 5 MICRO SWITCH 6 ELECTRO VALVE 7 THERMOSTAT 8 HOUR COUNTER ...

Page 6: ...tor 2 again through the heat exchanger or condenser 3 Finally the fan motor 4 expels the air back into the room through the front grill panel The condensed water is collected in the tank 5 A micro switch 6 stops the machine when the water in the tank reaches the correct level by raising the water float lever The humidistat 7 starts the functioning of the dehumidifier when the humidity is higher th...

Page 7: ...POWER will switch on confirming correct supply of power to the machine If the light WORKING is still off turn knob on the control panel clockwise until the light WORKING is ON The light DEFROST PAUSE will also switch on and after about 5 minutes the dehumidifier will start dehumidifying When the red light is ON ALARM the machine will not start one must check that the water tank is empty and that i...

Page 8: ...fting pump This allows condensed water to be drained into a floor waste or similar The pump will work automatically controlled by a ball cock placed inside the pump Before moving the machine remember to purge water from water tank If the pump cannot work correctly the compressor stops and the green light turns on In this case check the pipe situation Maximum head working pressure of the pump is ab...