file:///Applications/MAMP/htdocs/Frakco/TravelsoftREGENwoslidesHD.html[4/23/13 9:12:25 AM]
T
OLL
F
REE
800-967-1762 • D
IRECT
507-283-4416
FAX 507-283-4417
R
EGENERATION
I
NSTRUCTIONS
(M
ODEL
RV 1200
H
D
)
T
RAVELSOFT
HD
1
Turn
off
water supply.
(Relieve pressure from system by opening bottom
drain valve.)
2
Close bottom drain valve and turn valve lever counter clockwise to
backwash position.
(Figure #1)
Fig #1
3
Remove plastic cap from backwash connection, attach garden hose and
run
to drain.
4
Turn
off
water supply and let softener backwash for 5 minutes or until water runs clear.
5
Turn
off
water supply, remove garden hose from backwash connection and replace plastic cap.
6
Remove salt fill cap, turn valve lever clockwise back to conditioned water position, open bottom
drain valve and drain water from softener, close drain valve.
(This is done to make room for salt in
step # 7.)
7
Add 6 lbs. solar or rock salt
NOT PELLET TYPE
(approximately 10 cups)
, softener may have to be tipped slightly and gently shaken to get
all the salt in. Clean salt fill cap threads and replace salt fill cap.
DO NOT OVERTIGHTEN - CAP HAS 0-RING SEAL!!
8
Connect garden hose from outlet of softener and
run
to drain.
9
Turn
on
water supply slowly (approximately 1.5 gpm) for 15 minutes or until water is no longer salty. Turn
off
water supply. Connect garden
hose to RV and turn
on
water supply. Softener is now ready for service.
Open drain valve to drain water before storage - keep it from freezing.
The RV 1200 HD may be stored horizontally or vertically
(must be vertical when in use)
.
Never remove the softening material from inside the tank.
If softener is stored for a long period of time, a capfull of bleach may be added with the salt in step #7 to sanitize the softener.
Arrow in Backwash
Position