23
Now a window gives all possible settings: the parameters given in the paragraph relevant to basic programming and other
parameters relevant to the configuration of the inputs and outputs that are utilized for uses different from those in the standard
configuration.
Advanced configuration of inputs
MODE: Indicates the operating mode of the input.
• OFF: Input disabled
• Normal (AGC): enabled with automatic gain control
• Minimum gain: enabled with gain set to minimum
• Maximum gain: enabled with gain set to maximum
The modes with set gain can be used during the installation of the system for carrying out some checks.
BAND: indicates the frequency band associated to the input.
• Low: 10700÷11700 MHz band (from standard LNB).
• High: 11700÷12750 MHz band (from standard LNB).
• Wide: whole 10700÷12750 MHz band (from wide-band LNB).
POLARIZATION: indicates the polarization associated to the input.
• Vertical: vertical polarization.
• Horizontal: horizontal polarization.
SATELLITE: indicates the code in the DiSEqC (A/B/C/D) controls of the satellite associated to the input.
LNB LO: indicates the frequency of the local oscillator of conversion of LNB associated to the input. A different LNB can be set for
each input, a universal LNB can be selected or an LNB with four separated polarity or four independent LNBs.