The Auto VH1 Controller
The unit comes with a 15Amp, 3 point plug and
allows for a vacuum pump and a heater to be
connected. Note that the vacuum pump or the
heater unit may not exceed 10A or 15A in total.
The unit has a front panel and two 3 point AC
sockets.
One socket marked in Yellow to control the
Vacuum Pump.
One socket marked in Red to control the Heater
unit. Both sockets have a “on/off” switch which
must be in the “On” position for normal operation.
The switch can be turned off in an emergency as
an extra level of manual over-ride.
On the front panel of the unit you will find the
following:
OLED display in the centre indicates status and is
used for configuration.
Yellow LED: Indicates when the vacuum pump
socket is powered either directly or with the Auto
function.
Red LED: Indicates when the heater
socket is powered either directly or with
the Auto function.
Blue LED: Indicates when the unit is in
Auto mode and the on/off control will be
done based on the current configuration
settings.
The 4 arrow buttons control the unit. The
operating controls and configurations are
detailed below.
On the side of the unit there is a short
black pipe which must be connected to
your vacuum system. This pipe connects
the unit’s sensor to measure the vacuum
level to control the vacuum pump based on your settings.