background image

34

U32-4 FPI Direct Vent Gas Insert

LOGO

PLATE

HERE

LOGOPLA

TEHERE

LOGO

PLATE

HERE

LOGOPLA

TEHERE

92

95

STANDARD SIZE

DETAIL 'A'

91

93

REAR VIEW

FRONT VIEW

96

68

60

99

70

FRONT VIEW

94

99

51

59

65

97

98

71

72

73

FRONT VIEW

OVERSIZE

98

180

181

CUSTOM FACEPLATES

74

97

199

CUSTOM FACEPLATES
REAR VIEW

190

190

190

199

199

191

191

144

MOLDED FACEPLATE
FRONT VIEW

141

143

190

146

99

SEE DETAIL 'A'

142

147

145

147

190

147

147

147

147

SEE DETAIL 'A'

SEE DETAIL 'A'

PARTS LIST

 

402-919 

Complete Faceplate (Set) Contour 

 

   

with Black Trim-Oversize

51) *   

Faceplate Side Right - Oversize

59) *   

Faceplate Top - Oversize

60) *   

Faceplate Side Left Assy-Oversize

 

402-534 

Trims Pkg. Black - Oversize, Zero Clearance

65) *   

Faceplate Trim Right - Oversize

68) *   

Faceplate Trim Top - Oversize

70) *   

Faceplate Trim Left Assy - Oversize

97) 910-246 

2-way Gold Contact Switch

98) 910-330 

Fan Speed Control (120 V)

99) 904-569 

Fan Speed Control Knob (120 V)

 

400-917 

Complete Custom Faceplate (Set)

71) *   

Faceplate Side Right - Custom

72) *   

Faceplate Top - Custom

73) *   

Faceplate Side Left - Custom

74) 904-586 

Speed Control Knob 

  

 

c/w 

Spring 

Clip

 

FACEPLATE ASSEMBLY

          Part #     Description 

 

 

                                Part #     Description  

 

402-918 

Complete Faceplate (Set) 

 

   

Standard Contour with Black Trim 

91) *   

Faceplate Side Right - Standard

92) *   

Faceplate Top - Standard

93) *   

Faceplate Side Left Assy - Standard

 

402-532 

Trims Pkg. - Standard Black

 402-950 Trim 

Pkg. - Standard Brass

94) *   

Faceplate Trim Right - Standard

95) *   

Faceplate Trim Top - Standard

96) *   

Faceplate Trim Left Assy - Standard

97) 910-246 

2-way Gold Contact Switch

98) 910-330 

Fan Speed Control (120 V)

99) 904-569 

Fan Speed Control Knob (120 V)

 

 

402-933  Complete Faceplate (Set) Molded

141)  * 

Faceplate Side Right - Molded

142)  * 

Faceplate Top - Molded

143)  * 

Faceplate Side Left -Molded

144)  * 

Mounting  Bracket - Right

145) * 

Filler Bracket

146)  * 

Mounting Bracket - Left

147)  * 

Screw #8 x 3/4" Pan Head

180) 

400-950  Hearth Trim 1" - Regular

181)

  320-940  Hearth Trim 1" - Oversize 

180)

  400-926  Hearth Trim 2" - Regular

181)

  320-942  Hearth Trim 2" - Oversize 

180) 

400-928  Hearth Trim 4" - Regular

181) 

320-944  Hearth Trim 4" - Oversize

180) 

400-959  Hearth Trim 6" - Regular

181)

  320-946  Hearth Trim 6" - Oversize  

190)  * 

Screw #8 x 1/2" Black self-tapping

191)  * 

Screw #8 x 1/2" Brass self-tapping

199) 948-216  Regency

®

 Logo Plate

*Not available as a replacement part.

Summary of Contents for U32-LP4

Page 1: ...ce Installation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch a...

Page 2: ...ry equipped with a means to secure the unit INFORMATION FOR MOBILE MANUFACTURED HOMES AFTER FIRST SALE This FPI product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to th...

Page 3: ...fety 6 Speci cations 6 Gas Pressure Testing 6 Installation Into A Solid Fuel Burning Fireplace Or Factory Built Fireplace 6 Before You Start 6 Installation Checklist 7 Manufactured Mobile Home Additio...

Page 4: ...fference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the Sta...

Page 5: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Page 6: ...urning factory built replace may void the listing of the replace Check with your local inspector before commencing with this installation BEFORE YOU START Safe installation and operation of this appli...

Page 7: ...7 Test gas pressure Refer to section Gas Pipe Pressure Testing Check aeration system Refertosection GasInsertAeration System 8 Installstandardandoptionalfeatures Refer to the following sections a Bri...

Page 8: ...is inlet hole 3 Locate the center point where the vent will pass through the chimney above the appliance Move the appliance into the exact location where it is to be installed Ensure that the Insert i...

Page 9: ...t you can slide the brick tabs on to the screws easily but that the tabs are secure For the location of the side brick tab screws see diagram 1 5 Remove the brick tabs and slide the side brick panels...

Page 10: ...Left Log C 02 56 on the two pins as shown F 02 48 B 02 45 E 0 2 4 7 INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the...

Page 11: ...nect the fan switch wires by taking the black and red wires with the male ends in the grey harness and connect them with the wire connectors from the fan speed control 6 Connect the ON OFF switch wire...

Page 12: ...s with a black frame To install the frame simply hook the top door ange onto the top of the unit and swing the door towards the unit diagram 1 Be careful that the glass gasket does not roll up there m...

Page 13: ...n the unit Hook the top of the bay door over the ush door ange and swing the bottom against the bottom ange of the ush door Press down on the Bay Bottom bracket and push in until it clips behind the b...

Page 14: ...n Sheet 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out DC Sparker Kit Contains Qty Part Description 1 820 475 Bracket DC Sparke...

Page 15: ...nnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker Piezo Ignitor Ignitor Wire Piezo Ignitor Ignitor Wire DC Sparker 24 Install the 3 4 nylon plug to cover up the hole on th...

Page 16: ...oper flame appearance and glow on logs NOTE The battery in the DC Sparker Box will need to be replaced an nually 25 Connect the DC spark generator wires to the SIT Valve with the screw which is provid...

Page 17: ...to side trim 2 Lift unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit Unit should touch tabs on Bottom Trim Bracket Bottom Trim Bracket Push in Corners 3 Co...

Page 18: ...Top Frame is held in place by friction t if the frame needs to be adjusted bend the bracket accordingly Hinge Screen Door 7 Install the Left and Right Side Screen Doors in the fully open position by p...

Page 19: ...ace the switch box assembly over the boss on the rear left side piece and secure with one screw 28 9 Tuck the wires into the faceplate to keep them away from the insert using the clip provided Attach...

Page 20: ...to place Slide side ller bracket into gap between glass and re box Side Hook Slots 12 To put on the Hampton logo peel the sticker from the back of the logo and place it centered on the bottom left han...

Page 21: ...y harness and connect them with the wire connectors from the fan speed control Connect the ON OFF switch wires by taking the black and red wires with the female ends and connect them to the ON OFF swi...

Page 22: ...the 6 screws provided Left Side Door Pin on Door Frame Note If you nd that the Left or Right Side Screen Door is lower then the other use the spacer provided to help align the Doors The spacer is to b...

Page 23: ...ontrol wires for to the 120V wires 3 Install3AAAalkalinebatteriesintransmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to...

Page 24: ...a power failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wi...

Page 25: ...25 U32 4 FPI Direct Vent Gas Insert For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this manual INSTALLATION...

Page 26: ...ly push and release the black button on spark igniter until pilot lights Continue to hold the control knob in for approximately one minute then release the gas control knob The pilot ame should contin...

Page 27: ...nute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 3 and 4 If knob does not pop up when released stop and immediately call your servic...

Page 28: ...nder warranty GLASS GASKET If the glass gasket requires replacement use glass gasket Part 936 265 for the Bay Front and a tadpole gasket for the Flush Front Part 936 155 Top View of pilot ame Top View...

Page 29: ...rebox wall and lift out 8 Remove the 10 screws holding the Access Panel in place 9 Remove the Fan Air Duct by loosening the 3 screws squeeze the sides together to remove TO REMOVE FAN 1 Turn the unit...

Page 30: ...ng 13 Fire up the unit temporarily and check the manifold pressure 14 Reinstallthevermiculite embers rockwool logs and brick panels as needed 15 Close the door and replace the louvers 16 Fire up the u...

Page 31: ...lush Louvers Set Black 420 923 FlushLouvers Set Black Steel 25 420 940 Bay Louvers Set Black Gold 420 938 Bay Louvers Set Black 420 942 Bay Louver Set Black Steel 422 901 BrickPanelSet StandardBrown 4...

Page 32: ...7 904 390 Burner Ori ce LP 52 936 170 Ori ce Gasket 66 910 038 Pilot Assembly 3 Flame NG 910 039 Pilot Assembly 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 402 935 Log Set 402 572 E...

Page 33: ...oor Trim 112 904 196 1 Round Magnet 910 421 PilotOn Off3 ExtensionKnob SIT 910 422 FlameHi Low3 ExtensionKnob SIT 402 956 Gold Trim Bay Front 402 958 Steel Trim Bay Front Not available as a replacemen...

Page 34: ...Side Left Custom 74 904 586 Speed Control Knob c w Spring Clip FACEPLATE ASSEMBLY Part Description Part Description 402 918 Complete Faceplate Set Standard Contour with Black Trim 91 Faceplate Side Ri...

Page 35: ...Knob Black Cast Surround 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 Mounting Flange 195 Hampton Logo Plate 207 402 981 Cast Grill Set Top Bottom...

Page 36: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Page 37: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Page 38: ...________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________...

Page 39: ...ed by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replaceme...

Page 40: ...da FPI Regency Hampton and Palace are trademarks of FPI Fireplace Products International FPI replaces are designed with reliability and simplicity in mind In addition our internal Quality Assurance Te...

Reviews: