The FPI Direct Vent Gas Insert must be installed in 
accordance with these instructions. Carefully read 
all the instructions in this manual fi rst. Consult the 
building authority having jurisdiction to determine 
the need for a permit prior to starting the installation.

NOTE: 

 Failure to follow the instructions could cause 

a malfunction of the heater which could result in 
death, serious bodily injury, and/or property damage.  
Failure to follow these instructions may also void 
your fi re insurance and/or warranty. 

GAS PRESSURE 

TESTING

The appliance must be isolated from the gas supply 
piping system by closing its individual manual shut off 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than
1/2 psig. (3.45 kPa).

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must 
be disconnected.

Gas Input Capacity:

  

 

Natural Gas  23,500 Btu/h

 Propane 

21,500 

Btu/h

Min. Input:

 

Natural Gas  12,500 Btu/h

 Propane 

11,000 

Btu/h

Fuels: 

 Approved for use with both natural gas, 

and propane. Approved as is for use at 0' to 4,500' 
(0-1370m).

Electrical:

            120V A.C. system.

Circulation Fan: 

 Variable speed, 127 CFM.

Log Set: 

              Ceramic fi bre, 6 per set.

Vent System:

       3" co-linear aluminum fl ex  

 

             or 2" intake with 3" exhaust.

INSTALLATION INTO A 

SOLID FUEL BURNING 

FIREPLACE OR 

FACTORY BUILT 

FIREPLACE

The L234 Gas Inserts have been tested and 
approved to be vented into any masonry fi replace 
or approved solid fuel burning factory built fi replace 
that will allow the insert to physically fi t into the 
fi rebox. Refer to the "Minimum Fireplace Opening" 
section.

If the factory built fi replace* height is too low 
for your Insert, you may remove the smoke 
baffl e plate and damper from the factory built 
fi replace as long as these items are saved and 
are reinstalled in the event that the Insert is 
removed. NOTE: Any alterations made to the 
listed solid fuel burning factory built fi replace 
may void the listing of the fi replace.  Cutting 
any sheet-metal parts of the fi replace, in which 
the gas fi replace insert is to be installed, is 
prohibited.

If the factory-built fireplace has no gas 
access hole(s) provided, an access hole of 
1.5" (37.5mm) or less may be drilled through 
the lower sides or bottom of the fi rebox in a 
proper workmanship like manner. This access 
hole must be plugged with non-combustible 
insulation after the gas supply line has been 
installed. 

The  fi replace  and  fi replace chimney must 
be clean and in good working order and 
constructed of non-combustible materials and 
chimney cleanouts must fi t properly. Refractory, 
glass doors, screen rails, screen mesh, and 
log grates can be removed from the fi replace 
before installing the gas fi replace insert. Smoke 
shelves, shields and baffl es may be removed if 
attached by mechanical fasteners. A tight seal 
between the gas fi replace insert fl ue collar and 
the fi replace chimney must be made to prevent 
heat loss.

*Check with your local inspector before commencing 
with this installation.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however,  we are required 
by the Canadian Safety Standards and ANSI 
Standards to make you aware of the following:

General Safety Information

1)

  The appliance installation must conform 

with local codes or in the absence of local 
codes, with CAN/CSA B149.1 (in Canada) 
or the National Fuel Gas Code ANSI Z223.1 
NFPA 54 in the U.S.A. This appliance should 
be installed by a qualifi ed gas fi tter technician 
only.

2)  Installation and repair should be done by a 

qualifi ed service person.  

3)  The appliance should be inspected before 

use and at least annually by a professional 
service person. More frequent cleaning 
may be required due to excessive lint from 
carpeting, bedding material, animal hair, etc.  
It is imperative that control compartments, 
burners and circulating air passageways of 
the appliance be kept clean. 

4)

  See general construction and assembly 

instructions. This appliance may only be 
installed in a vented, noncombustible fi replace.

5)

  This appliance is Listed for bedroom  installations 

when used with a Listed Millivolt Thermostat. 
Some areas may have further requirements, 
check local codes before installation.

6)

  Always connect this appliance to a vent system 

vent that is run (or routed) to the outside of the 
building envelope. Never vent  to another room 
or inside a building. Make sure that the vent 
is properly sized and is of adequate height to 
provide the proper draft.  

7)

  Inspect the venting system annually for blockage 

and any signs of deterioration.   

8)

  Any glass removed for servicing must be 

replaced prior to operating the appliance.  

9)  WARNING: Failure to position the parts in 

accordance with the diagrams in this manual 
or failure to use only parts specifi cally 
approved with this appliance may result in 
property damage or personal injury.

10)

 To prevent  injury, do not allow anyone who is 

unfamiliar with the operation to use the fi replace.  

Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.

"

WARNING

: This fi replace has been converted 

for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."

Summary of Contents for L234

Page 1: ...allation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any elec...

Page 2: ...vide you with all the warmth and charm of a fireplace at the flick of a switch The L234 NG and L234 LP have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark...

Page 3: ...g 14 SIT Valve Description 14 Conversion Kit 536 969 from NG to LP 15 Optional Brick Panel Installation 17 Screen door install removal 18 Glass door install removal 18 Contour or Contemporary Faceplat...

Page 4: ...t and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Ma...

Page 5: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECT...

Page 6: ...6 Regency L234 Direct Vent Gas Insert DIMENSIONS...

Page 7: ...PPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHI...

Page 8: ...himneycleanoutsmustfitproperly Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace beforeinstallingthegasfireplaceinsert Smoke shelves shields and baffles...

Page 9: ...optional features Refer to the following sections where applicable a Brick Panels b Log Installation c Faceplate d Hearth Trim e Backing Plate f RemoteControl brickpanelsare mandatory with remote con...

Page 10: ...non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Unless otherwise stated the clear...

Page 11: ...of the termination cap NOTE Simpson Duravent can only be used with 3 and 3 liners INSTALLATION WITH 3 3 LINERS Part Description 948 305 3 Flex 35 ft intake exhaust 946 529 FPI Co linear DV Vertical Te...

Page 12: ...the 4 screws that hold the vent restrictor plate in place 2 Remove the 3 collar from the top plate by undoing the 4 screws NOTE The screws are secured from the underside of the top plate Underside of...

Page 13: ...NOTE 1 Final gas connection should be made after unit is in place to avoid damage to the liner when pushing the unit into position 2 Mill pac may be used instead of high tempture silicone and screws...

Page 14: ...ve is in the OFF position 2 Loosenthe IN and or OUT pressuretap s turningcounterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Lig...

Page 15: ...INSTALLATION 1 Open the left and right side faceplate panels 2 Turn off the gas supply 3 Remove the bottom louver by pulling out 4 Remove the glass door a Pull off the left side spring hook that hold...

Page 16: ...ig 3 17 Using the allen key as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 3 Fig 4 WARNING Do not overtighten the screw Recommended to grip the wrench by the short side...

Page 17: ...ck panel by carefully placing it against the back wall of the firebox and rest it on the rear log tray Back Brick Panel Rear Log Tray 3 Slide the right side brick panel into position and secure in pla...

Page 18: ...side down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 1 Remove the glass door 2 Hook the screen door...

Page 19: ...ft and right side panels to show keyhole mounting 2 Open the left and right side faceplate panels of the faceplate 3 Mount the faceplate onto the unit by aligning the 4 key hole slots in the faceplate...

Page 20: ...rom the sleeve and connect them to the wires from the unit as shown in diagram 10 9 Close the right side faceplate panel 10 Remove the remote receiver bracket from the left side of the unit by undoing...

Page 21: ...12 and put back in place see diagram 13 NOTE Ensure connectors are tucked in behind the mounting bracket to allow the side faceplate panel to close easily Diagram 12 Diagram 13 15 Re install the remot...

Page 22: ...soft surface to prevent scratching Backing Plate Installation Customize Backing Plate The inside of the backing plate may be cut as required using a metal cutting blade Do not cut the outside edges Th...

Page 23: ...ight Corner Backing Plate 9 Place the right side corner backing plate over the top and right side backing plate Push in place to secure see diagram 5 Repeat for left side Completed Backing Plate Insta...

Page 24: ...panels to show mounting of hearth trim a The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece b Cut the top of the bottom piece of the he...

Page 25: ...y remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Fit log 2 711 into the pins on the rear log tray 2 711 3 Place log 2 714 on the base o...

Page 26: ...g 2 713 into the pin on log 2 714 and rest the right side of the log on the burner plate pushing it against the tab 2 712 2 713 2 714 2 713 6 Place log 2 715 into the pin on log 2 712 and rest the rig...

Page 27: ...e right side of the burner as shown 8 Fit log 2 716 into the pin on log 2 712 Right side of Burner 2 713 2 716 2 712 Also place a few embers along the burner tube next to log 2 713 Separate platinum e...

Page 28: ...28 Regency L234 Direct Vent Gas Insert INSTALLATION Completed Log Set Installation 2 711 2 716 2 715 2 712 2 713 2 714...

Page 29: ...surfaces and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be p...

Page 30: ...iring rate rate noted on label at 15 minutes 2 Ifrequired adjustingtheprimaryairtoensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CA...

Page 31: ...seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait LIGHTING PROCEDURE During the first few...

Page 32: ...und when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burnertube s andlogsand...

Page 33: ...ANCE CAUTION ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP...

Page 34: ...Whileholdingthehookturn it upside down and place it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 5 Remove the logs...

Page 35: ...fan by sliding the fan forward and lift up and out 14 Remove the ground screw which holds the ground wire Ground Wire 15 Replace the fan NOTE Bendtheconnectorclipsdownbefore re installing the fan cov...

Page 36: ...lace it into the middle opening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 7 Disconnect the gas connection to the valve 8 Disconnect the...

Page 37: ...ews Rear Log Tray Removed 14 Remove the 12 screws that hold the valve tray to the firebox and carefully pull out 15 Replace the valve 16 Reverse steps 14 1 11 Remove the burner by undoing the 3 screws...

Page 38: ...el Set Standard Brown 536 902 Brick Panel Set Standard Red 9 Brick Panel Right 10 Brick Panel Left 11 Brick Panel Back 511 031 Brick Clip 12 536 523 Flue Adaptor Assembly 13 Valve Shield 14 536 091 Pi...

Page 39: ...CEPLATE ASSEMBLY Part Description 60 536 918 Contemporary Faceplate 61 536 914 Contour Faceplate 62 910 246 Burner ON OFF Switch 63 910 330 Fan Speed Control 120 V 64 904 569 Fan Speed Control Knob 65...

Page 40: ...Insert PARTS LIST BACKING PLATE HEARTH TRIM ASSEMBLY Part Description 536 922 Backing Plate 81 Left Side 82 Right Side 83 Top 84 Left Corner 85 Right Corner 536 940 Hearth Trim 86 Top 87 Bottom Not a...

Page 41: ...Regency L234 Direct Vent Gas Insert 41 NOTES...

Page 42: ...42 Regency L234 Direct Vent Gas Insert NOTES...

Page 43: ...nsportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days...

Page 44: ..._________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial...

Reviews: