WARRANTY

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit 
thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original purchaser of a 
Excalibur Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime 
Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date 
of purchase and parts only thereafter.

Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating 
and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, 
ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, 
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and 
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any 
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided 
that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of 
installation. Reported damage after this time will be subject to rejection.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated 
for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from 
unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. 
ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence 
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical 
systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty 
on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Summary of Contents for Gas Insert U35-LP1

Page 1: ...tallation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any ele...

Page 2: ...th all the warmth and charm of a fireplace at the flick of a switch The U35 NG1 and U35 LP1 have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promise...

Page 3: ...AFETY LABEL Serial No Decal 4 REQUIREMENTS MA Code CO Detector for state of Massachusetts only 5 INSTALLATION Important Message 6 For Your Safety 6 Gas Pressure Testing 6 Specifications 6 Installation...

Page 4: ...ence the label on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts For the State...

Page 5: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Page 6: ...erationofthisappliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following General Safety Information 1 The appliance i...

Page 7: ...tory Built Fireplace b Minimum Fireplace Dimensions c Minimum Clearnces to Combustibles d Venting 2 Make the gas connection Refer to the Gas Connection section 3 Installthe3 fluelinertotheslidingconne...

Page 8: ...CLEARANCES KENSINGTON FRONT COMBUSTIBLE MANTEL CLEARANCES Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facin...

Page 9: ...ING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE This appliance is designed to be attached to two 3 76mm co linear aluminium flex running the f...

Page 10: ...essure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the limits speci...

Page 11: ...res by taking theblackandredwireswiththefemaleends and connect them to the ON OFF switch 7 Tuck the wires into the faceplate to keep them away from the insert using the clip provided Attach the clip t...

Page 12: ...e frame simply hook the top door flange onto the top of the unit and swing the door towards the unit diagram 6 Be careful thattheglassgasketdoesnotrollup theremust be a gap between the gasket and the...

Page 13: ...o unclip the Bay Bottom bracket from the flush door and then swing up and unhook from the top flush door flange To remove the Bay Door the Flush Front together pull the hook from the slot in the botto...

Page 14: ...ck and red wires with the male ends in the grey harness and connect them with the wire connectors from the fan speed control Connect the ON OFF switch wires by taking the black and red wires with the...

Page 15: ...pins on the Door Frame Repeat for Right Side Screen Door Note It will be easier to put the Screen Door in place by starting with the bottom hinge Left Side Door Pin on Door Frame Note If you find that...

Page 16: ...s with the wire connectors from the fan speed control Place clips over wires and tuck into side trim 2 Lift the unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under...

Page 17: ...Bottom Frame Hinge Location 5 Install Spring Hinges to the Left and Right Side of the bottom of the firebox using 2 screws per hinge 7 Install the Left and Right Side Screen Doors by placing over top...

Page 18: ...ply is needed for the fan blower operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should...

Page 19: ...smitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to remote mode The remote control is now ready for operation OPTIONAL REMO...

Page 20: ...in a few minutes as the glass heats up DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Che...

Page 21: ...und will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burnertube s andlogsandismadeofadifferent...

Page 22: ...ats up Never operate the appliance without the glass properly secured in place or with the door open 7 Do not use this appliance if any part has been under water Immediately call a qualified service t...

Page 23: ...door on the stove and check the seal Straighten adjustment wire 7 Remove the Burner Rear Log Support assembly by removing the 2 screws 1 on each side and sliding the assembly to the left to free the b...

Page 24: ...ord Replacing fan Reverse above steps Sealfanaccesspanelusinghightemperature Burner Rear Log Support Assembly After removing the screws slide to the left to remove the assembly from the firebox base L...

Page 25: ...k up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak testing 15 Fire up the unit temporarily 16 Check the manifold pressure 17...

Page 26: ...Black Steel 21 Top Flush Louver 23 Bottom Flush Louver 320 932 Bay Louvers Set Black Gold 320 934 Bay Louvers Set Black 320 935 Bay Louvers Set Black Steel 25 Top Bay Louver 27 Bottom Bay Louver 320...

Page 27: ...320 564 P Valve Assembly LP 56 910 190 Piezo Ignitor and Nut 57 910 478 Valve S I T NG LPG 59 Valve Tray 66 910 034 Pilot Assy 3 Flame S I T NG 910 035 Pilot Assy 3 Flame S I T LP 67 904 689 Orifice...

Page 28: ...e 102 Flush Glass Retainer 106 940 318 P Side Glass 107 936 243 Gasket 108 940 317 P Center Glass 111 Door Trim 112 904 196 Magnet 1 Round 910 421 Pilot On Off 3 Extension Knob 910 422 Flame Hi Low 3...

Page 29: ...Right 95 Trim Top 96 Trim Side Left Assy 97 910 246 Burner ON OFF Switch 98 910 330 Fan Speed Control 120 V 99 Faceplate Filler 320 933 Molded Faceplate Complete 141 Molded Faceplate Right 142 Molded...

Page 30: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Page 31: ...portation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of...

Page 32: ...Printed in Canada FPI fireplace products are designed with reliabilityandsimplicityinmind Inaddition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our d...

Reviews: