IN
– VA10
- 19 -
© Future Products Group
SERVICING
Electrical Protection
VISAIR CABINETS
-
SERVICING
Circuit Breaker
The lighting and control circuits are protected by a
circuit breaker, located on the control panel.
The louvered panel must be removed to access the
circuit breaker.
If the breaker cannot be reset, call an electrician to
check the circuits.
Lighting
VISAIR CABINETS
-
SERVICING
Caution
DO NOT service the lights, without isolating the cabinet at the main switch or
unplugging it from the electricity supply.
LED Lighting
Strips
Light is provided by an LED strip, under the
top of the cabinet.
The LED modules have
a very long life, but if
they fail, the complete
strip should be
replaced.
The LED strips are self-
adhesive, with soldered
connections.
Ensure correct polarity when reconnecting.
Be sure to replace this plastic cover.
LED Power
Supplies
The LEDs are fed with a 24Vdc
constant voltage. They consume
approximately 17 W per metre of strip
length.
The power supply is located behind the
back panel, to the side of the mains
connector.