PREPARATION FOR USE
The Foxcart is shipped completely assembled except for the handles. Attaching hardware is in-
serted into the mounting holes where the handles are to be mounted for your convenience.
Verification of Options and Strapping should be checked before use. Incorrect Primary Supply
Voltage or Strapping could cause damage or improper DC Output.
CAUTION:
WHEN THE FOXCART IS PLUGGED INTO THE AC OUTLET, ALL OF THE
STRAPPING TERMINALS ARE “HOT”. CAUTION MUST BE USED TO PRE-
VENT SHORTS OR ELECTRICAL SHOCK.
Figure 3 shows how strapping should be for different input source voltages. Select the appropriate
chart that is the same as your hangar power and compare it with the chart. If it is strapped differ-
ently correct the strapping.
The “X, Y and Z” posts are for output to the utility plug on the front of the Foxcart. To set correct
strapping, the unit must be plugged into the power source and a voltage measurement taken from
each post to case ground.
CAUTION:
BEFORE RE-STRAPPING, DISCONNECT THE AC CABLE FROM THE POWER
SOURCE.
Select the post closest to 115 VAC and strap it to post “W” (See FIGURE 3)
If your Foxcart is 380 VAC or more, the Stepdown Transformer should be installed. If not, your utility
outlet voltage will be high and could cause damage to equipment.
CAUTION:
TERMINALS “X AND Y” WILL BE HIGH VOLTAGE.
CAUTION:
IF TERMINALS “X AND Y” DO NOT READ NEAR 115 VAC, DO NOT USE THE
UTILITY PLUG. CONTACT AUTHORIZED FACTORY REPRESENTATIVE FOR
CORRECTION.
-7-