3448 W. Mockingbird Ln.
Dallas, TX 75235
PHONE: 214/358-4425
FAX: 214/358-1519
TITLE: FOXCART AC INPUT VOLTAGE STRAPPING
DRAWING NO: 400-0001-003
PAGE: 1 OF 1
REV: B
DRAWN BY: SE
APPROVED BY:
DATE: 10/01/01
208
230
240
FOXCART MODEL 1200
2
3
4
B
2
3
4
2
3
4
E
F
208V
2
3
4
B
2
3
4
2
3
4
E
F
230V
2
3
4
B
2
3
4
2
3
4
E
F
240V
2
3
4
B
2
3
4
2
3
4
E
F
380V
2
3
4
B
2
3
4
2
3
4
E
F
440V
2
3
4
B
2
3
4
2
3
4
E
F
480V
FOXCART MODEL 1600/2000
2
3
4
B
2
3
4
2
3
4
E
F
208V
2
3
4
B
2
3
4
2
3
4
E
F
225V
2
3
4
B
2
3
4
2
3
4
E
F
440V
2
3
4
B
2
3
4
2
3
4
E
F
480V
FOXCART MODEL 1600-C ONLY
208 TO 250 VAC LINE
15 AMP FUSES
UTILITY PLUG SET-UP
PLUG THE INPUT CABLE OF THE FOXCART INTO HANGAR POWER. USING A VOLTMETER, CHECK THE VOLTAGE AT
TERMINALS "X" AND "Y" TO CHASSIS GROUND. SELECT THE MEASUREMENT THAT IS NEAREST TO 120 VAC.
DISCONNECT HANGAR POWER, CONNECT STRAP BETWEEN SELECTED TERMINAL AND POST "W" TIGHTEN NUTS,
RECONNECT POWER AND VERIFY THAT 120 VAC IS AT THE UTILITY PLUG.
NOTE: IF INPUT AC POWER IS 380 VAC OR ABOVE AND STEPDOWN TRANSFORMER IS INSTALLED. TERMINALS W, W,
Y AND Z ARE DISCONNECTED.
FIGURE 3.
foxtronics
incorporated
Y
X
W
Z
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A
A
C
C
D
D
A
C
D
D
C
A
A
C
D
D
C
A
A
C
D
D
C
A
A
A
C
C
D
D