11
©2021 FOXTECH All Rights Reserved
Thor 210 Hybrid Hexacopter
User Manual
Tab. 5 Common faults and maintenance methods
Caution: This system does not support low power consumption. When the
system is not in use, please remove the battery or set a switch to cut off the electrical
connection between the battery and the system. The system does not support hot plug.
The controller will be damaged by hot plug in case of use and maintenance.
than 50 hours.
air. In some cases, tilt the fuel tank
properly.
11
Control Circuit
The control circuit or sensor is
damaged.
Contact the manufacturer.
12
Insufficient
Power Output
It's time for maintenance.
Contact the manufacture.
13
Air Filter
The air filter element is too dirty.
Clean the filter element with
gasoline.
14
Spark Plug
Remove the spark plug and press it
in the red coil. Contact the ignition
head of the spark plug with the
engine block, and turn the starting
head. If the ignition light is yellow or
weak, replace the spark plug.
15
The voltage
drops rapidly
after take-off
Battery
Low battery voltage
Before takeoff, turn the
three-position-switch to "run" and
wait for about 1 minute.
16
miscellaneous
Mechanical parts are damaged.
Contact the manufacturer.