Installation (with notes)

Hardware Installation

Software Installation and Configuration

A

IDU, IDUS installed to drone.

Please install the IDU, IDUS to the proper position of the UAV to ensure that the installation position is stable, 
firm and no sloshing.
Ensure that there is no occlusion and interference in the range of pod activity.
Make sure the IDU module is dry without blocking in the shock absorption range. Please keep certain 
activity space redundancy for power cord, network cable ,7P transfer wiring, 
Ensure locking between pod and IDU, buckle well and prevent shedding during flight.
Do not plug the pod when the aircraft is electrified.
Please check the damping shock absorber regularly for breakage and leakage. In case of breakage, please 
replace in time. Do not disassemble the damper ball frequently, or touch the ball with sharp objects to avoid 
breakage.

B

Datalink sky-end installation, antenna installation

Please install the datalink in the appropriate position of the aircraft and ensure good ventilation and heat 
dissipation.
Make sure the cable (4P wire, serial line) is firmly connected, no loosening, no breakage of the cable. 
Please keep a certain activity space redundancy for power cord, network cable, serial port.

C. IDU and videolink sky-end Power Supply
IDU / IDUS R2S (with sky end, ground end) supports 12-25v power supply.
5.8G videolink (including sky-end, ground-end) support only 12v power.

D. Pod assembly

A. Computer Network Section Settings
Preparation.
After the software is installed, ensure that the pod, datalink(sky, ground end) works properly, the network 
cable is connected to the computer, and the computer is not connected to the wifi at this time. Through 
local connection → Properties → Internet Protocol Property 4 (TCP / IPv4) → General Settings → Use the 
following IP address: (Different data link settings are different, see the corresponding data link user manual 
for details) → Confirm
5.8G Datalink :(also optional to get an IP address automatically, but make sure your computer wifi is off, and 
not connected to another network)
IP Address :192.168.42.10 Subnet Mask :255.255.255.0 Default Gateway (ignored)
Rain Bow-R2S (1.4g band):
IP Address :192.168.42.10 Subnet Mask :255.255.255.0 Default Gateway (ignored)
After setting up, open the GCS software to click on the connection → select the corresponding pod. When 
the image appears, the full display control settings of the pod can be realized

B. PC software installation and setup
 Refer to corresponding GCS usage instructions

Summary of Contents for EH640

Page 1: ...User Manual V1 0 Foxtech EH640 30x Optical Zoom IR Thermal Camera with 3 axis Gimbal 2020 03...

Page 2: ...Once used it is deemed to be an endorsement and acceptance of the entire contents of this statement Please read the instruction manual carefully and strictly follow the requirements of this manual to...

Page 3: ...las Pod IDU IDUS Video Transmission System Ground Station Software Extension Module Installation with notes Hardware Installation Software Installation and Configuration Installation and setup methods...

Page 4: ...sassemble gateway damping Datalink 5 8G videolink 2km R2S 15km video data link R2PRO integrated video datalink IRIS 4G video datalink Software GCS Android Windows Custom QGC Android Windows TOPGUN sof...

Page 5: ...system diagram wiring instructions wire sequence definition SBUS professional pod wiring diagram 4P network port 7p expansion port Power supply 12 25V Serial port 1 Serial port 2 The receiver needs se...

Page 6: ...iring notices Pod IDU IDUS Brief functional description supported pod type etc The pod system is divided into two levels professional load lightweight load Adapt to different levels of multi rotor dro...

Page 7: ...ns detailed SBUS usage instructions Mission management module IRIS IRISI1 uses industrial high performance CPU equipped with 4G communication module external expansion of 3 channels of CAN bus interfa...

Page 8: ...y connected no loosening no breakage of the cable Please keep a certain activity space redundancy for power cord network cable serial port C IDU and videolink sky end Power Supply IDU IDUS R2S with sk...

Page 9: ...modification take change 42 segment to 1 segment as an example 1 pod electrified and connected the pod to the computer through the wire the pod works normally after about 15 seconds the computer recog...

Page 10: ...ptical Zoom IR Thermal Camera User Manual 2020 FOXTECH All Rights Reserved 8 4 Camera IP modification Open any browser enter 192 168 42 108 After entering the following interface username password are...

Page 11: ...hen the following password modification interface appears click cancel After entering the setup interface click Settings Network Settings General Settings Change the IP address and default gateway 42...

Page 12: ...ettings the equipment used shall prevail Pod RTSP Common Address Main stream rtsp admin admin ip 554 cam realmonito Channel 1 subtype 0 Secondary stream 1 rtsp admin admin ip 554 cam realmonito Channe...

Page 13: ...l Property 4 TCP IPv4 General Settings Use the following IP address Different data link settings are different see the corresponding data link user manual for details Confirm 5 8G Datalink also option...

Page 14: ...digital link CAN transfer When operating in an environment with large pre and post flight temperature differences e g winter aircraft moving from indoors to outside Calibration is recommended before...

Page 15: ...s Reserved 13 Operating Pods gcs support remote real time download of camera side video photos 1 Operational steps view download interface as shown below can download video MP4 style photo jpg offline...

Page 16: ...ve the damage to break the circuit Software setup check Make sure the computer network is set correctly and the computer turns off the wifi when connecting the datalink The computer is not connected t...

Reviews: