![Foxjet SoloSeries 45 Operation Manual Download Page 23](http://html1.mh-extra.com/html/foxjet/soloseries-45/soloseries-45_operation-manual_2325497023.webp)
Thermal Jet
5780-329 Operations Manual Rev J
Page 18
Message Editor continued: User Defined Time Codes
When
User Defined
selected,
Define Time Code
button
appears
Tabular format: codes printed taken from
table. Use default codes (default Hour codes
shown) or edit table to suit your requirements.
Periodic format: example above illustrates a
shift code implemented by using a periodic
quarter hour code. ’A’ prints from 23:30 -
06:59, ’B’ from 07:00 - 15:29, and ’C’ from
15:30 - 23:29.
Sequential format: minute code shown.
Minute 00 = AA, 01 = AB, 02 = AC, etc.