4. Technical Parameters 

Type S-Box Plus 

Number of Strings 

Number of Poles 

Specs. 

S-Box Plus 

Unit pre-wired with 16 * MC4 

connectors and 1 * M23 quick 

connection for AC 

 
 

Ratings according to IEC: EN 60947-3:2009/A1:2012/C1:2013/A2:2015 Cat PV-1 based on 

switching both the + and the - pole:

 

VDC 

300 

600 

800 

1000 

1200 

1500 

25 

25 

25 

25 

25 

16 

 
 

Technical Parameter

 

String voltages   

300~1500 Vdc 

String current   

25 / 25 / 25 / 25 A 

Number of strings 

Switch wiring 

Operating voltage 

100~270 Vac 

Nominal voltage 

230 Vac 

Nominal current 

30 mA 

Start up (loading) current 

average 100 mA 

Switch on action current 

max 300 mA 

Communication 

RS485 

Recommended operating temperature range 

-20 - +50 °C 

Max. operating temperature   

before automatic switch off 

+70 °C 

Storage temperature range 

-40 - +85 °C 

Protection degree 

IP66 

Protection level 

Class II 

DC switch disconnect according to 

CE 

Certification 

EN 60947-1&3 

Number of mechanical operations 

10000 times 

 

 

 

Summary of Contents for S-Box Plus

Page 1: ...User Manual In order to prevent improper operation before use please carefully read this manual S Box Plus...

Page 2: ......

Page 3: ...ely isolate PV modules S Box Plus is powered by a motorized X type switch and can therefore be located directly at the PV modules This minimizes the amount of cabling with dangerous high voltage and l...

Page 4: ...the DC switch goes off LED will on when the DC switch is on D Terminal Contains AC input and RS485 AC input Signal input and power supply of the S Box Plus RS485 RS485 communication consists of interf...

Page 5: ...and rivet terminal Step 2 Insert the parts into the cable Step 3 Tighten wires as shown in the figure below Tightening torque 0 6 0 1N m then insert cable respectively to pin hole Ribs are towards bod...

Page 6: ...er tightening is 1 5mm E Water proof vent valve Prevent condensation and fog improve the service life Heat dissipation and balance pressure difference improve product integrity Chemical resistance hig...

Page 7: ...5 3 2 Dimensions...

Page 8: ...g voltages 300 1500 Vdc String current 25 25 25 25 A Number of strings 4 Switch wiring 8 Operating voltage 100 270 Vac Nominal voltage 230 Vac Nominal current 30 mA Start up loading current average 10...

Page 9: ...ox is not blocked Do not install in places where gas or flammable substances may be present Avoid electromagnetic interference that can compromise the correct operation of electronic equipment The slo...

Page 10: ...ping pliers Screwdriver 5 4 Installation Steps Prepare two fixed blocks The two fixing blocks are locked on the box body with M5 self tapping screw Choose the place you want to install the S Box Plus...

Page 11: ...holes with electric drill make sure the holes are at least 50mm deep and then tighten the expansion tubes Insert expansion tubes into the holes and tighten them Install the fixing blocks with expansio...

Page 12: ...not plagiarize partially or fully copy including software etc and no reproduction or distribution of it in any form or by any means is permitted All rights reserved FOXESS CO LTD WUXI BRANCH Add No 1...

Reviews: