1. Introduction 

In most photovoltaic systems, the DC isolator is integrated into the DC/AC power inverter. After 

switching off the DC isolator, the cables between the DC solar modules and DC/AC power inverter 

running through the building are still subject to up to 1000 Vdc. In the event of a fire, firefighters are 

exposed to a very serious source of potential danger. The S-Box Plus provides the solution

 

to this 

problem. It directly disconnects the DC current in close proximity to the solar modules and creates a 

safer situation for firefighters. 

Basic Features: 

·

 

AC power shut down=automatic DC power shut down 

·

 

Auto reset when AC power is back=DC power is back 

·

 

Easy to install   

2. System Advantages 

2.1 Easy installation 

S-Box Plus can be installed without disassembling the shell. 

2.2 Gain valuable time in case of a fire 

S-Box Plus works according to standard international firefighter routines, resulting in valuable time lost 

in AC power is shut down, S-Box Plus will automatically switch off and isolate DC cables running 

between the PV modules and the inverter. Firefighters only have to follow their regular routine and do 

not have to waste valuable time eliminating the risk of DC power still present at these cables. In case 

the AC power is not shut down and the temperature reaches 70°C at the S-Box Plus unit it will 

automatically shut down the DC power as extra safety system. 

2.3 Completely isolate PV modules 

S-Box Plus is powered by a motorized X-type switch and can therefore be located directly at the PV 

modules. This minimizes the amount of cabling with dangerous high voltage and leads to a completely 

powerless situation in the house, maximizing safety when needed. 

2.4 Auto reset 

A power down situation can occur at any time and for many reasons. S-Box Plus has an auto reset 

function. S-Box Plus automatically switches off if the regular AC power is down for more than 6 sec and 

automatically switches on when the regular AC power is on again. No manual reset is necessary every 

time the power has been down! After check of the safety situation and when the AC main power is 

reconnected automatically the S-Box Plus will switch on the DC power. 

2.5 For use in industrial and residential photovoltaic installations 

By using this standard concept unit for either 1 or 2 strings it is possible to combine unlimited number of 

units to fix every size of installation. As option it is possible to connect all units to the same AC source in 

order to create a separate DC on-off operation by switching this specific AC source on-off that will 

operate all units at the same time. Again, reset is done automatically AC on = DC on, AC off = DC off. 

These units can be easily retrofitted to existing or new installations. 

2.6 Indication of DC switch status 

S-Box Plus integrated with status indicator for customers to confirm the switch status.   

2.7 RS485 

The RS485 interface on the S-Box Plus can provide grid voltage temperature, switching status and other 

information via external communication. 

Summary of Contents for S-Box Plus

Page 1: ...User Manual In order to prevent improper operation before use please carefully read this manual S Box Plus...

Page 2: ......

Page 3: ...ely isolate PV modules S Box Plus is powered by a motorized X type switch and can therefore be located directly at the PV modules This minimizes the amount of cabling with dangerous high voltage and l...

Page 4: ...the DC switch goes off LED will on when the DC switch is on D Terminal Contains AC input and RS485 AC input Signal input and power supply of the S Box Plus RS485 RS485 communication consists of interf...

Page 5: ...and rivet terminal Step 2 Insert the parts into the cable Step 3 Tighten wires as shown in the figure below Tightening torque 0 6 0 1N m then insert cable respectively to pin hole Ribs are towards bod...

Page 6: ...er tightening is 1 5mm E Water proof vent valve Prevent condensation and fog improve the service life Heat dissipation and balance pressure difference improve product integrity Chemical resistance hig...

Page 7: ...5 3 2 Dimensions...

Page 8: ...g voltages 300 1500 Vdc String current 25 25 25 25 A Number of strings 4 Switch wiring 8 Operating voltage 100 270 Vac Nominal voltage 230 Vac Nominal current 30 mA Start up loading current average 10...

Page 9: ...ox is not blocked Do not install in places where gas or flammable substances may be present Avoid electromagnetic interference that can compromise the correct operation of electronic equipment The slo...

Page 10: ...ping pliers Screwdriver 5 4 Installation Steps Prepare two fixed blocks The two fixing blocks are locked on the box body with M5 self tapping screw Choose the place you want to install the S Box Plus...

Page 11: ...holes with electric drill make sure the holes are at least 50mm deep and then tighten the expansion tubes Insert expansion tubes into the holes and tighten them Install the fixing blocks with expansio...

Page 12: ...not plagiarize partially or fully copy including software etc and no reproduction or distribution of it in any form or by any means is permitted All rights reserved FOXESS CO LTD WUXI BRANCH Add No 1...

Reviews: