7. Appendix I Cleaning Fiberoptic Connections
The unit has an FC/APC (or other optional) optical connector for very high optical return loss
performance. The units are specified into singlemode fiber i.e. 9/125 micron core diameter.
Full performance is specified only for low return loss optical plant - meaning that the fiber
must be fusion spliced and all connections or splices must have a return loss greater than -60
dB. With these guidelines in mind, link lengths beyond 20 kilometers. (DFB based products)
can be achieved with high performance. Specific performance and/or design assistance is
available by request from Foxcom.
If there is low/no signal or noisy signal at a Foxcom module, the connector should be
cleaned. Dirt on the inside connector tip can impair the flow of light causing problems in
signal transmission. Foxcom modules are sealed but dirt can occasionally enter.
8. Appendix II Installing a Standalone Unit
To install the 7320T or 7320R Standalone:
1. Place the 7320 unit on the standalone flange, matching the holes.
2. Using four screws (#4 or #6) secure the unit and the flange to the wall.
3. Apply AC power to the standalone power supply unit.
4. Connect the 7320 unit to the power supply. The Laser LED should be lit.
5. All remaining steps are the same. Refer to Setting Up the Transmitter on page 13, and
Setting Up the Receiver on page 15.