Page 1: ...Copyright Four Winds Spas 2017 Specifications subject to change UltraXStream Swim Spa Owner s Manual ...

Page 2: ...pa dealer and purchase details To locate your spa s Serial Number simply find the metal plate on the bottom corner of your spa usually on the right panel if you are facing the control panel and list the nine digit number printed on the plate Finally please complete and return the enclosed Warranty Registration Card within 15 days of receiving your spa in order to have your spa listed in Four Wind ...

Page 3: ...ure Spa Modes and BWG App Page 11 Four Winds Spas Warranty Information Pages 12 13 USA and Europe Wiring Diagrams Pages 14 15 Four Winds Quick Start Guides NOTE Please read this manual in its entirety as it contains important safety and maintenance information WARNING RISK OF SEVERE INJURY OR DROWNING DANGER Entrapment may occur if hair is entangled knotted or snagged in a suction fitting drain or...

Page 4: ...nce from the inside of your swim spa or when you are wet Do not attempt to remove the light housing cover s with out lowering the water level below the light housing cover The Unit must be hardwired to a supply circuit protected by a Ground Fault Circuit Interrupter GFCI The GFCI is required by most building codes and should be provided by installer tested before each use Consult the GFCI manufact...

Page 5: ...ness while other medication may affect heart rate blood pressure and circulation Observe a reasonable time when using the swim spa Long exposures at high temperatures can cause high body temperature hyperthermia Enter and exit the swim spa slowly Wet surfaces can be very slippery Proper chemical maintenance of swim spa water is necessary to maintain safe water and prevent possible damages to swim ...

Page 6: ...ed to ensure clearance required for delivery Example gates walls debris fences trees overhead power lines etc Clearance required turning a corner can be equal to the length of the spa Any trimming of trees and brushes leveling of delivery area must be done before delivery and is at the responsibility of the customer ELECTRICAL REQUIREMENTS USA Pack Requirements Your 220 volt spa pack will require ...

Page 7: ...the sun can dry the material and cause it to crack If the cover needs to be cleaned use only anti petroleum products and simply wash the underside with water and let dry Water Chemistry Every 5 7 days the chemical level should be tested to ensure the pH Alkalinity Calcium Hardness and Bromine Chlorine levels are correct It is important to know the volume of water in your spa to calculate and adjus...

Page 8: ...housing clockwise or counterclockwise to increase or decrease water pressure The fixed 2 size jets are not adjustable on some models Swim Spa Lighting Your swim spa may be equipped with a LED lighting system on each 3 5 jet internal 1 2 main underwater light housings water features and perimeter lighting These are optional packages but all are controlled from the swim spa top side control panel Se...

Page 9: ...lorine Bromine levels should be between 3 0 5 0 ppm Test weekly or as needed to maintain proper Bromine levels Do not use with Chlorine Chlorine Functions as sanitizer and is generally used in larger spas and pools Spas should be between 1 5 3 0 ppm Test weekly or as needed to maintain proper Chlorine levels Do not use with Bromine Test Strips Test strips measure the levels of Chemicals CH and Ph ...

Page 10: ...like Economy Mode but not to the set temperature Instead the temperature will be heated within 20 F 10 C of the set temperature Revolution Series Programing Dual Temperature Ranges The spa has two programmable temperature ranges high range from 80 104 F and low range from 50 99 F In each range a specific temperature can be programed When the spa is not in use it can be switched to the low range to...

Page 11: ...date as long as it is owned by original purchaser Plumbing Labor warranty is 3 Years Replaceable service items light bulb fuses pillows gaskets o rings etc are not covered under this warranty but are warranted to be free from defects in materials at time of delivery to the original purchaser This Limited Warranty does not apply if the failure is caused by or contributed to by any of the following ...

Page 12: ...structions G F C I Breaker Concerns If after you wire your spa and apply power the GFCI breaker will not stay engaged the G F C I breaker is not wired correctly Check G F C I breaker wiring chart following this section and verify that all of your connections are correct Generally if the breaker will not stay engaged it is a wiring problem on the neutral wire Note The neutral and ground wire cannot...

Page 13: ...Z For 50 HZ Systems 1 to 3 Pumps Use 1 X 32 AMP Breakers For 50 HZ Systems 4 Pumps Use 2 X 32 AMP Breakers Use 6 Gauge Wire For Supply Connections use Conductors sized on the basis of 60 Degrees Celsius Amperage but rated minimum of 90 Degrees Celsius Torque Range for Main Terminal Block 27 30IN LBS 31 3 34 5 KG ...

Page 14: ...P a g e 14 251 Mayfield Dr Smyrna TN 37617 P 615 220 8879 F 615 220 8944 FourWindsSpas com ...

Page 15: ...P a g e 15 251 Mayfield Dr Smyrna TN 37617 P 615 220 8879 F 615 220 8944 FourWindsSpas com ...