![Four-Faith F8 26 Series User Manual Download Page 90](http://html1.mh-extra.com/html/four-faith/f8-26-series/f8-26-series_user-manual_2324525090.webp)
F8X26 Series Router
User Manual
Fields
Sub field
Offset Example
Description
SOF
1
FE
0xFE
Length
1
03
The length of data
Command Send
2
24 5D
Fixed to 24 5D
Data
Destination
2
10 0E
Destination node
address
Query
command
1
02
Fixed to 02
FCS
1
66
Frame check
sequence
SRSP
Fields
Sub field
Offset Example
Description
SOF
1
FE
0xFE
Length
1
01
The length of data
Command Send
2
64 5D
Fixed to 64 5D
Data
State
1
00
00 = success,
Others = error
FCS
1
38
Frame check sequence
AREQ:
Fields
Sub field
Offset Example
Description
SOF
1
FE
0xFE
Length
1
0C
The length of data
Command Send
2
44 5D
Fixed to 44 5D
Data
State
1
00
00 = success,
Others = error
Destination
2
10 0E
Destination node address
MAC
address
8
8B D9 D1
01
00 4B 12 00
Low byte come first
Node type
1
01
00=coordinator
01=router
02=end device
FCS
1
D1
Frame check sequence
4.4.3.7 OTA Query node address
SREQ
Fields
Sub field
Offset Example
Description
SOF
1
FE
0xFE
Length
1
09
The length of data
Command Send
2
24 5C
Fixed to 24 5C
Data
Query
command
1
03
Fixed to 03
MAC address
8
8B D9 D1 01
Low byte come first