Page 31 of 56
56000
--- 56000 bps
57600
--- 57600 bps
115200
--- 115200 bps
Property
:
Databit, Parity, Stopbit
8N1 --- 8 Databit, No parity, 1 Stopbit
8E1 --- 8 Databit, Even parity, 1 Stopbit
8O1 --- 8 Databit, Odd parity, 1 Stopbit
Bind
:
Center1: the data from the port send to center 1
Center2: the data from the port send to center 3
Center3: the data from the port send to center 3
Center4: the data from the port send to center 4
Center5: the data from the port send to center 5
ALL: the data from the port send to all centers
Close: send to none
COM2
The same as above
RS485
The same as above
3.6 IO function
IP MODEM support 2 digital I/O and 1 Analog input,can custom data string to query data or
trigger IO state.
3.6.1 Digital I/O
I/01
Input:work as digital input port
Output:work as digital output port
Indication:will output low level when IP Modem connect data
center;output high level when disconnect from data center
Port
support COM/GPRS/ SMS
Protocol
Modbus:you can query or control IO status through modbus tcp
command
Custom:you can custom command to query IO status
Summary of Contents for F2816 V2
Page 52: ...Page 52 of 56 ...